My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
437
>
2300 - Underground Storage Tank Program
>
PR0506406
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/17/2023 3:32:05 PM
Creation date
6/3/2020 9:58:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0506406
PE
2361
FACILITY_ID
FA0002313
FACILITY_NAME
WILSON WAY CHEVRON
STREET_NUMBER
437
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
15113052
CURRENT_STATUS
01
SITE_LOCATION
437 N WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506406_437 N WILSON_2009-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 0 <br />A <br />Facility is Not EquipRed With Fill Riser Containment Sumps 0 <br />Fill Riser Containment Sumps are Present, but were Not Tested 0 <br />Test Method Developed By: 0 Sump Manufacturer D Industry Standard %Profession ; it Engineer <br />0 Other (Specify) <br />Test Method Used: D Pressure 0 Vacuum 'ti�Iydrostati, <br />0 Other (Specify) <br />Test Equipment Used: ki,4C.0�+ 7% 5,, - ',i; Equipment Resolution: <br />Fill Sump # 1 Fill Sump #Z- Xj' k Fill Sump # <br />1111 Sump # <br />Sump Diameter: <br />Z�V I <br />Sump Depth: <br />ag <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />Condition of sump prior to <br />testing <br />Portion of S2Mp Tested <br />ZrI as <br />Sump Material: <br />%7> <br />Wait time between applying <br />Pressure/vacuum/water and <br />tit <br />starting test: <br />Test Start Time: <br />Af-i <br />Initial Re���.. <br />t,!2:?, -7 X �' <br />Test End Time: <br />4 :2L PI -1 1/: 39 AV -1 <br />Final Reading (RF): <br />4tu z 44 <br />Test Duration: <br />16 to I 1-t % li�t <br />Change in Reading (RF-Ri): <br />0,ovv?e-, 0 vcx-� V <br />PasslFail Threshold or Criteria: <br />Test Result: <br />Pass ❑Fail ass 0 Fail 0 Pass 0 Fail <br />0 Pass 0 Fail <br />Is there a sensor in the sump? <br />)R�Yqs C No SYes 0 N 0 Yes 0 No <br />0 Yes GNo <br />_� <br />Does the sensor alarm when <br />'9yes 13 No 0 NA <br />either product or water is <br />tYes DNo DNA DYes 0 N DNA <br />3Yes n -No DNA, <br />detected? <br />Was sensor removed far testing? <br />'gYes 0 No 0 NA —'XYes —D No 0 NA 0 Yes -0 No 0 NA <br />I]Yes ONo DNA <br />Was sensor properly replaced and <br />Yes 0 No 0 NA, 0 No C) NA D Yes 0 No 0 NA <br />ilYes 0 N [INA <br />verified functional after testing?. <br />
The URL can be used to link to this page
Your browser does not support the video tag.