My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
437
>
2300 - Underground Storage Tank Program
>
PR0506406
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/17/2023 3:32:05 PM
Creation date
6/3/2020 9:58:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0506406
PE
2361
FACILITY_ID
FA0002313
FACILITY_NAME
WILSON WAY CHEVRON
STREET_NUMBER
437
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
15113052
CURRENT_STATUS
01
SITE_LOCATION
437 N WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506406_437 N WILSON_2009-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
May *i`8 11 11:43a Reliable Petroleu 209-845-8953 p.2 <br />0 <br />QNITQRING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions ;Yithin the State of California <br />rtilthority Cited.' Chz wer 6.7. Health and Safety Code; Chapter 16, Division 3, Tilie 23, California Code of Regulations <br />This form must be used to do ument testing and servicing of monitoring equipment. A separate certification or report must he prepared for each <br />monitoring system control pan i by the technician who performs the work. A copy of this form must be provided to the tank system ownerloperator. <br />The owner/operator must subiT t a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. Generallnforma n <br />Facility Name: Wilson Ifty Chevron Bldg. 'No.: <br />Site Address: 437 N. Wil on Wa City: Stockton CA Zip: 95205 <br />Facility Contact Person: 1'► ian Mehroke Contact Phone No.: (209) 942-2344 <br />Make/Model of Monitoring ystem: Veeder- Root TLS -350 Date of Testing/Servicing: 2/15/2011 <br />B. Inventory of Equi meet Tested/Certified <br />a.,nccn uicw...v ...... ......�.. ... '—'----------__-.__- <br />Tank 1D: T1:87 <br />Tank ID: T2:91 <br />® In Tank Gauging Probe. <br />Model: 847390-109 <br />® in -Tank Gauging Probe. <br />Model: 847390-109 <br />® Annular Spacc or Vault Senso <br />Model: 794390-407 <br />® Annular Space or Fault Sensor. <br />Model: 794390-407 <br />® Piping Sump I Trench Sensor( ). <br />Model: 794380-20B <br />® Piping Sump / Trench Sensor(s). <br />Model: 794380-208 <br />® Fill Sump Sensor(s). <br />Model: 794380-208 <br />® Fill Sump Senser(s). <br />Model: 794380-208 <br />® Mechanical Line Leak Detect _ <br />Modcl: VMI 99LD-2000 <br />01 Mechanical Line Leak Detector. <br />Model: R.J. FX1V <br />❑ Elo=nic Line Leak l3etecto <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / Hi_h-Level Se sor. <br />Model: <br />❑ Tani: Overfill / Hi;h-Level Sensor. <br />Model: <br />❑ Other (specify equipment tyjx and model in Scction E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Pace 2). <br />TankID: <br />Tank ID: <br />i ❑ In -Tank Gauging Probe. <br />Model: <br />❑ in -'rank Gauging Probe. <br />Model: <br />❑ Annular Space or Vault S=SL <br />Model <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Piping Sump 1 'french Sensor ). <br />Model: <br />❑ Piping Sump,' Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s}. <br />Model: <br />❑ Fill Sump Selsor(s). <br />Model: <br />❑ Iviechanical line Leak Detect r. <br />Model: <br />❑ Mccbanical Line Leak Detector. <br />Model: <br />❑ Electronic Linz Leak Detecto <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill 'High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment typeand model in Section E on Page 2). <br />❑Other (specify equipment type and model in Section E on Page 2)• <br />DispenserID: 1&2 <br />Dispenser ID: 3&4 <br />® Dispenser Containment Sens( (s). <br />Model: 330212-M <br />® Dispenser Containment Sensor(s). <br />Model: 330212-001 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispcnser Containment Float -) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5&6 <br />Dispenser ID: 7&8 <br />® Dispenser Containment Sans s). <br />Model: 3 30 21 2-00 1 <br />® Dispense Containment Sensor(s). <br />Model: 330212-001 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Contai nment Float ) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containnten Sens r(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Flo s) and Chain(s). <br />p <br />❑ Disperser Containment Floats) and Chain(s). <br />flf the facility contains MoreFntcs or atspenscrs, copy ulrS lurin. J11L UUG all 111ML w+ w *• J •u .. •..• , ... Y .••��• • • .••_ •---• <br />C. Certification -I c ify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached o this Certification is information (e g. manufacturers' checklists) necessary to verify that this information is <br />correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also <br />attached a copy of the eport, (check all tit at apply): N System set-up Z Alarm history report <br />Technician Name (print): <br />Certification No.: A301 <br />Testing Company Name: <br />Testing Company Addre! <br />Guadalupe Sanchez <br />Signature: <br />License. No.: 883706 <br />Reliable Petroleum Services Inc. PhuuC NU.. (209) 845-8586 <br />11930 Horseshoe Road, Oakdale CA 95361 Date of Testing/Servicing: 211512011 <br />Page 1 of 3 <br />Rev (2.08) <br />