Laserfiche WebLink
&� SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 eh: sigov org/ehd/u iitiii.html <br />UNDERGROUNDO+ PROGRAM O. <br />. <br />Facility name: <br />ISOO 1) <br />Facility address: <br />Facility contact: Title: Phone. <br />l'Yl /Vl lJ j -i 1- l Gfz <br />Monitoring panel: _ Piping system: <br />-0 V Pressurized ❑ Suction ❑ t <br />Inspection type: '�Y��/ <br />rVL_.i. Mnnitnrina Certification ❑ Installation ❑ Other: <br />m <br />1 <br />2 <br />3 <br />4 <br />5 <br />:d Operator: Exp. date: Inspection <br />Date: <br />UST # r <br />Product <br />overfill prevention: <br />)(Mechanical ❑ Audible/visual ' <br />_❑ M2-RPrev ❑ M-3 Both <br />ICC Service Technician Exp. ®ate: Manufacturer's Training: v m =� x, . -7 /'7 /' <br />a0A-� • 4 1 1,1110 1Z x -'2 a <br />Code Section l i ) HSC=California Health & Safety Code; CCR=California Code of Regulations V <br />R <br />v -v niatinn RV=RP-nB2t Violation <br />CCR 2637 <br />CCR 2711 <br />HSC 2529. <br />CCR 2632 <br />CCR 2712 <br />7 i CCR 2712(b) <br />No permit to operate <br />Secondary containment: (a) test not performed; (e) test report not sub <br />provided to the EHD at least 48 hours Prior to conducting the test <br />& (c) Current Unified Program Consolidated Forms not on file with the EHD <br />Current financial responsibility documents not on file with the EHD <br />Monitoring Program (Monitoring & Response Plan) is not current or al <br />8 <br />CCR 2643(d) <br />9 <br />HSC 25292.1_ <br />10 <br />CCR 2632(c)(2) <br />• 11 <br />CCR 2630(d) <br />12 <br />HSC 25291(b) <br />13 <br />CCR 2636(f)(1) <br />14 <br />CCR 2631(a) <br />15 <br />HSC 25291(a)(2 <br />16 <br />CCR 2636(c)(1) <br />17 <br />HSC 25291(0 <br />18 <br />CCR 2635(b)(1) <br />19 <br />CCR 2635(b)(2) <br />20 <br />CCR 2636(a) <br />• 21 <br />HSC 25291(e) <br />22 <br />CCR 2650 <br />23a <br />CCR 2715(a) <br />23b <br />CCR 2715(b) <br />23c i CCR 2715(c), (d), (e) <br />-1 23d i CCR 2715(f) <br />thin 30 days; (f) test notification <br />and tank form) <br />the local <br />Monitoring and/or response plan is not onsite <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6'/z years, (M1) <br />written performance claims pertaining to release detection systems for 5 years, or records of repairs, linings, and <br />upgrades for the life of the tank. Monitoring records include: (1) date and time of all monitoring or sampling; (2) <br />monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) results of <br />sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring equipment, <br />ground water elevations, or other test results; (6) results of inventory readings and reconciliations. <br />Daily monitoring of suction piping (pre -January 1, 1984) not performed <br />UST system is not operated to prevent unauthorized release, including spills and overfills <br />Monitoring system is not present in the interstitial space of a double walled UST/piping (M1) <br />UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity (MMI) <br />UST system monitoring equipment is not operational <br />Failed to maintain a continuous monitoring system for underground piping & UDC that to activates an (M1) <br />audible and visual alarm or stops flow of roduct at the dispenser when it detects a leak <br />Primary containment is not product tight <br />Secondary containment for UST system is not tight <br />All releases in secondary piping do not flow to a collection sump <br />Line leak detector(s) not installed tM11 <br />Spill container not installed, failed to contain a minimum capacity of five gallons, or failed to provide (M21 <br />a means to keep the spill container empty <br />Overfill prevention system was overridden or failed to meet overfill requirements in this section (M2, <br />Failed to have secondary containment or continuous monitoring (includes conventional suction piping) <br />Water in 21 containment not removed, analyzed & properly disposed of <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight hours (M1', <br />was not recorded; (e) escaped secondary containment, not cleaned up after eight hours, or a sudden loss of <br />product was not reported to the EHD within 24 hours <br />Failed to inform the EHD of a change of designated operator within 30 days <br />Designated operator did not possess a current ICC UST System Operator certification <br />Designated operator monthly inspection: (c)(1) alarms not documented; (c)(2-4) spill containers, UDCs, and <br />sumps (if necessary) not inspected; (c)(5) required test dates not checked or noted; (c)(6) employee training not <br />verified; (d)(e) month!y inspection reports not maintained on site for at least 12 months <br />Designated operator employee training: (1) not performed; (2) not current for at least one employee on site; (3) <br />not ke t <br />e+r e+e- ea rc rs. esti. TITLE: <br />Page 1 <br />UST INSPECTION REPORT <br />