Laserfiche WebLink
SAN jOAQUIN COUNTY 0 <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />CONTINUED <br />`| 21, g/ <br />/) <br /># <br />Code Section <br />VIOLATION(S) HSC=California Health & Safety Code; CCR=California Code of Regulations V R <br />24 <br />CCR 2638 <br />Monitoring equipment certification: (a) not performed annually; (d) test report not submitted within 30 days; (e) test <br />notification not provided to the EHD at least 48 hours prior to conducting an installation, repair, replacement, <br />calibration, or certification; (f) performed, and failed to affix a tag/sticker on each monitoring equipment <br />component that was certified, repaired, or replaced <br />25 <br />CCR 2638 <br />Annual line leak detector test: (a) not performed; (d) test report not submitted within 30 days (Mi) <br />26 <br />HSC 25284.2 <br />Annual spill containment testing not performed <br />27 <br />CCR 2636(f)(4) <br />Annual line tightness test not performed if positive shutdown or fail safe not present <br />28 <br />CCR 2661 (f) <br />Repair for tank or piping not tested for tightness within 30 days of completion of the repair (M2) <br />29 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) <br />30 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (Mi) <br />31 <br />HSC 25292.5 <br />ELD testing not performed on a system located within 1000'of publicwell, or failures not repaired and retested <br />32 <br />1 CCR 2661 <br />Permit to repair UST system not obtained <br />33 <br />HSC 25286(a) <br />Permit to alter monitoring system not obtained <br />34 <br />HSC 25298(b) <br />Permit to temporarily close UST system not obtained <br />35 <br />HSC 25298(c) <br />Permit to dose UST system not obtained <br />36 <br />HSC 25299(a)(91L <br />Tampering with or disabling leak detection devices or alarms <br />37 <br />HSC 25298(a) <br />Illegally abandoned UST system <br />38 <br />HSC 25281.5(b)(2) <br />Unburied fuel piping at marinas not visually inspected at least monthly or log not kept <br />39 <br />CCR 2631.1 (a) <br />UST system is not compatible with the substance stored <br />40 <br />CR 2636(f)(6) <br />y generator monitoring system not checked daily or log not kept (MI) <br />281.5(b)(3 <br />bel piping not visually inspected at least monthly or log not kept (MI) <br />EE <br />uner violations <br />EMD2x-02-0O2REV 120S Page UST INSPECTION REPORT <br />Compatibility and permeability requirements: (a) UST system is not compatible with the substance stored; (b) <br />42 <br />CCR 2631.1 results of the compatibility and permeability testing requirements listed in subsections CCR 2631 (b) and (d) for a <br />__L! �sstem installed after July 1, 2004, were not submitted <br />43 <br />HSC 25290.1 (c)(1) Primary containment not liquid or vapor tight <br />44 <br />HSC 25290.1 (c)(2) Secondary containment not liquid or vapor tight <br />45 <br />HSC 25290.1 (c)(3 ) Secondary containment not constructed to prevent water intrusion <br />46 <br />HSC 25290.1 (d) Monitoring system not maintained to detect water intrusion into the secondary containment, or the entry of liquid <br />I <br />HSC 25290.2(gl_ or vapor from the primary containment into the secondary containment 1 <br />1 <br />47 <br />HSC 25290.1 (e) Interstitial liquid measurement method, constant vacuum, or constant pressure in the interstitial space of the UST <br />system not maintained <br />SC 25290.10) UST system not tested by one, of the following methods prior to use: (1) Enhanced leak detection; (2) inert gas <br />I <br />5290.2�i) pressure test approved by SWRCB; (3) test method deemed equivalent to (1) or (2) by the SWRCB <br />uner violations <br />EMD2x-02-0O2REV 120S Page UST INSPECTION REPORT <br />