My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3940
>
2300 - Underground Storage Tank Program
>
PR0507837
>
COMPLIANCE INFO_2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 4:46:23 PM
Creation date
6/3/2020 9:59:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010
RECORD_ID
PR0507837
PE
2361
FACILITY_ID
FA0008057
FACILITY_NAME
TRACY TRUCK AND AUTO STOP
STREET_NUMBER
3940
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95304
APN
21220004
CURRENT_STATUS
01
SITE_LOCATION
3940 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0507837_3940 N TRACY_2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
348
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
APR-30-2010 FRI 05: 45 I'M P. 045 <br /> 04/2812010 13:26 661393a* CHUCK HILL PAGE 06/07 <br /> EPIC Compliance Systems, LLC <br /> 10M 86YOM SUR--150-53n Swe,CA 94C6S-ConnC1*rL[r-*aEN3430 <br /> MECHANICAL LEAK DETECTOR TEST DATA SHEET <br /> Site Name — LrA;y Truck Ston <br /> Site Address, 3940 N Tracv Blvd Trac CA 95304 <br /> Test Information <br /> 2 3 4 <br /> Product 87 91 carside Diesel West Histo East HFIo <br /> Manufacturer VM1 VMI VM1 VMI VMI <br /> Model 99 LD2000 99 LD2000 99 1-132000 LD 3000 LD 3000 <br /> Resiliency 200 ml 110 MI 75 ml N/A - <br /> Opening Time 2 sec 3 Sac 3 sec 17 sec <br /> Test Leak Raft(ml/min)9ph 3 GPM 3 GPM 3 GPM 3 GFIH 3 GPH <br /> Metering PSI 22/..32 17/27 17/32 21135 <br /> L PASS I FJAU1 pass pwcm pass pass Fal I <br /> L <br /> Comments: <br /> This lethr ceriffies that the leak detector test(s) were performed at the above referenoW facility according to the <br /> equipment manufacturers proceftras and limi1aflons and the results as Usted are to my knowledge tve and correct. <br /> The mechanical leak detacw test passnail is determined using a low flow threshold trip rate of 3 gph at 10 PSI. <br /> Inspected By., EPIC Compliance Systems, LLC <br /> Technician: kefth Hjj n Signature: <br /> Date, 010 rrme: <br />