D. Results of Testing/Servicing <br /> Software Version installed: 8.01 <br /> Complete the followina checklist: <br /> ® Yes ❑ No* Is the audible alarm operational? <br /> ® Yes ❑ No* Is the visual alarm operational? <br /> ® Yes ❑ No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> ® Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their <br /> proper operation? <br /> Yes ❑ No* If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? <br /> ® WA <br /> Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system <br /> ❑ N/A detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate positive shut-down? (Check all that apply) <br /> ❑ Sump/Trench Sensors; ❑ Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor <br /> failure/disconnection? ❑Yes; ❑No. <br /> ❑ Yes u No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no mechanical overfill prevention <br /> ® WA valve is installed),is the overfill warning alarm visible and audible at the tank fill point(s)and operating properly? if so,at what percent <br /> of tank capacity does the alarm tri er? <br /> ❑ Yes* M No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the <br /> manufacturer name and model for all replacement parts in Section E,below. <br /> 0 Yes* ® No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply)❑Product; El Water. If <br /> es,describe causes in Section E,below. <br /> ® Yes ❑ No* Was monitoring system set-up reviewed to ensure proper settings?Attach setup reports,if applicable <br /> Yes 0 No* Is all monitoring equipment operational per manufacturer's specifications? <br /> *In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: ALL UST TANKS HAVE OVERFILL VALVES AND ALL DISPENSER PANS HAVE BRAVO FLOATS 1 THRU SON AUTO <br /> SIDE 11 THRU 18 ON DIESEL SIDE ALL OPERABILITY TESTED. REPLACED FAULTY FLOAT ON DISPENSER PAN#12 RETESTED <br /> GOOD ALL NOW OPERATING AS DESIGNED. <br /> NOTE: ALSO TESTED SENSORS TO ABOVEGROUND TANKS SENSORS ALSO OPERATING AS DESIGNED. <br /> 1-3 TANK 5 AST MAIN ANNULAR <br /> L4 TANK 6 AST SYPHON ANNULAR <br /> L5 AST TRANSITION SUMP <br /> Monitoring System Certification Page 2 of 4 12!07 <br /> 2 2/21/07 <br />