My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3355
>
2300 - Underground Storage Tank Program
>
PR0508352
>
COMPLIANCE INFO_1999-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2021 3:22:58 PM
Creation date
6/3/2020 9:59:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2007
RECORD_ID
PR0508352
PE
2361
FACILITY_ID
FA0008044
FACILITY_NAME
CHEVRON STATION #1731*
STREET_NUMBER
3355
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12618007
CURRENT_STATUS
01
SITE_LOCATION
3355 E HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508352_3355 E HAMMER_1999-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ONIT NG SYSTEM CETIFI TION <br /> se By All Jurisdictions Within the State of Califon <br /> Authority Cited:Chapter 6.7, and Safety Code;Chapter 16,Division 3 Title 23, alifomia Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulafing UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name:CHEVRON 208118 City: STOCKTON CA Zip:95212 <br /> Site Address: 3355 E.HAMMER LANE Contact Phone No: 477-3699 <br /> Date of Testing/Service: 04/25/2006 <br /> Facility Contact Person: MANAGER <br /> Make/Model of Monitoring System:VRTLS350 Work Order Number: 2242412 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: 1 Tank ID: 2 <br /> X In-Tank Gauging Probe. Model: MAG X in-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: 407 Annular Space or Vault Sensor. Model: 407 <br /> X Piping Sump/Trench Sensor(s). Model: 208Piping Sump/Trench Sensor(s). Model: 208 <br /> Fill Sump Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> 71 Electronic Line Leak Detector. Model: PLLD X Electronic Line Leak Detector. Model: PLLD <br /> Tank Overfill/High-Level Sensor. Model: MECHANICAL X Tank Overfill/High-Level Sensor, Model: MECHANICAL <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Tank ID: Tank ID: <br /> In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s) Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank OverfilUHigh-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Others equipment(specify eq p type and model in Section E on page 2). <br /> rspenser : 1/2 Dispenser ID: 3/4 <br /> ®Dispenser Containment Sensors) Model:208 -Xj Dispenser Containment Sensor(s) Motel:208 <br /> X❑Shear Valve(s). -X-1 Shear Valve(s) <br /> F]Dispenser Containment Float(s)and Chain(s). 7 Dispenser Containment Float(sjand Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: 7/8 <br /> X Dispenser Containment Sensor(s) Model:208 Dispenser Containment Sensor(s). Model:208 <br /> ® Shear Valve(s). 71Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9/10 Dispenser ID: 11/12 <br /> Dispenser Containment Sensor(s) Model:208 X Dispenser Containment Sensor(s). Model:208 <br /> ® Shear Valve(s). X Shear Valve(s). <br /> 10 Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> .If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify,that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): ®System set-up ®Alarm history report <br /> Technician Name(print): RAYMOND SIMMS Signature: <br /> Certification No.: 006-05.0282 License.No.: <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 8501 N.MoPac Expressway,suite 400,Austin,TX 78759 Date of Testing/Servicing: 04/25/2006 <br /> Monitoring System CertificationPage 1 of 3 Based on CA form dated 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.