Laserfiche WebLink
P,Tanimok3gy ONITORING SYSTEM CERTIFICATION <br /> F=e By All Jurisdictions Within the State of Cal/fomi <br /> Authority Cited:Chapter 6.7,Hea and Safety Code;Chapter 16,Division 3 Title 23, rfomia Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: CHEVRON 208118 City: STOCKTON CA Zip:95212 <br /> Site Address: 3355 E.HAMMER LANE Contact Phone No:477-3699 <br /> Facility Contact Person: MANAGER Date of Testing/Service: 06/09/2003 <br /> Make/Model of Monitoring System: TLS 350 Work Order Number: 2226763 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: 1 Tank ID: 2 <br /> In-Tank Gauging Probe. Model: D In-Tank Gauging Probe. Model: <br /> X Annular Space or Vault Sensor. Model: 794390-407 Annular Space or Vault Sensor. Model: 794390-407 <br /> X Piping Sumpfrrench Sensor(s). Model: 794380-208 X1Piping Sumpfrrench Sensor(s). Model: 794380-208 <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: 848480-001 X Electronic Line Leak Detector. Model: 848480-001 <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). El Other(specify equipment type and model in Section E on page 2). <br /> Tank ID: Tank ID: <br /> In-Tank Gauging Probe. Model: M In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: <br /> Piping Sumpfrrench Sensor(s). Model: Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: El Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overrill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Dispenser : 1/2 Dispenser ID: 7/8 <br /> ®Dispenser Containment Sensor(s) Model:794380-208 X Dispenser Containment Sensor(s) Model:794380-208 <br /> Shear Valve(s). FXJ Shear Valve(s) <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 3/4 Dispenser lD: 9/10 <br /> ® Dispenser Containment Sensor(s) Model:794380-208 Dispenser Containment Sensor(s). Model:794380-208 <br /> FlShear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: 11/12 <br /> ® Dispenser Containment Sensor(s) Model: 794380-208 X Dispenser Containment Sensor(s). Model:794380-208 <br /> Shear Valve(s). X Shear Valve(s). <br /> 10 Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): System set-up report; 0 Alarm history report 0 <br /> PRINTED NAME:RHOME DESBIENS SIGNATURE: <br /> COMPANY: Tanknology PHONE NO: (800)800-4633 <br /> page 1 of 3 Based on CA form dated 03/01 <br />