Laserfiche WebLink
0 0 <br /> 4.Measure the distance from the tank top(inside)to the top of 36• METHOD 1 <br /> the standpipe.Subtract 1 inch from this measurement and <br /> record the distance. <br /> 5.Subtract the second distance from the first and record this <br /> value as reading`B"on the Installation Checklist. <br /> CALCULATION AND COMPARISON <br /> 1.Subtract reading`B"from reading"A". <br /> 2.Compare this value to the table of Maximum Allowable gill 011111mill 011 11110 <br /> Deflections shown on the Installation Checklist. FIGURE 15-1 <br /> 3.Vertical deflection in excess of these values indicates improper If this method is not practical,additional tanks may be buried in <br /> installation and voids the tank warranty. the same installation hole.After emptying existing tanks to less <br /> ® ®® than one-quarter capacity,remove the surface slab.Enlarge the <br /> excavation for the new tank,leaving as much backfill as possible <br /> around existing tanks. It may be necessary to install shoring to <br /> SINGLE WALL TANKS make sure that existing tanks do not move and that sufficient <br /> Single wall tank installations may require release detection backfill remains.The new tank must be installed by following the <br /> monitoring,which can include inventory control,automatic tank procedures in this guide. Remember to leave a minimum of 18 <br /> gauging,vapor monitoring or ground water monitoring.Check inches between tanks.The backfill material must be the same as <br /> with federal,state,and local officials for requirements in your that specified in Section 3. <br /> area. <br /> DOUBLE WALL TANKS <br /> Xerxes double wall tank has an interstitial space for the METHOD 2 <br /> containment of leaked product from the primary tank.The tank, <br /> as supplied,will have a minimum of one monitor fitting that <br /> provides access into the space between the primary(internal) <br /> and secondary(external)tank walls.If a double wall tank is <br /> sloped,the monitor should be at the low end. <br /> WITH A DRY INTERSTITIAL SPACE <br /> The monitoring system and method is the responsibility of the <br /> tank owner and/or operator.A safe electronic or mechanical FIGURE 15-2 <br /> system should be used to detect either incoming water or <br /> product.The monitor system should detect leakage near the <br /> bottom of the tank.Monitoring can be done through the monitor <br /> fitting provided. If the tank is sloped,the lowest elevation must be <br /> the monitoring end. <br /> WITH LIQUID-FILLED INTERSTITIAL SPACE <br /> In a liquid-filled monitoring system,the interstitial space is filled <br /> with liquid at the point of manufacture.The system enables the <br /> owner to have continous monitoring or to conduct a tank <br /> tightness test(Tru Check®).It also provides the ability to use an <br /> electronic reservoir monitoring system. <br /> Additional Xerxes tanks can be installed at existing locations if <br /> proper foundation support exists.The method of installation is the <br /> responsibility of the owner. It is required,however,that one of the <br /> following methods be used.The preferred method is to install a <br /> new tank in a separate hole at least 3 feet from the original hole. <br /> Caution must be exercised in keeping unusual surface loads off <br /> existing tanks.The natural barrier of undisturbed soil between <br /> tanks must be maintained. <br />