My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3355
>
2300 - Underground Storage Tank Program
>
PR0508352
>
COMPLIANCE INFO_2008-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2021 4:50:21 PM
Creation date
6/3/2020 9:59:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2011
RECORD_ID
PR0508352
PE
2361
FACILITY_ID
FA0008044
FACILITY_NAME
CHEVRON STATION #1731*
STREET_NUMBER
3355
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12618007
CURRENT_STATUS
01
SITE_LOCATION
3355 E HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508352_3355 E HAMMER_2008-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
323
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQU'IN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd/unitiii.htmi <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility address: Inspection Date: <br /> 1-2,1112 <br /> # Code Section VIOLATION(S) HS-C=California Health&Safety Code;CCR=Califomia Code of Regulations V R <br /> V=Violation;RV=Repeat Violation IV <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days;(e)test <br /> notification not provided to the EHD at least 48 hours prior to conducting an installation,repair,replacement, <br /> 24 CCR 2638 calibration,or certification;(f)performed,and failed to affix a tag/sticker on each monitoring equipment <br /> component that was certified,repaired,or re laced <br /> 25 CCR 2638 Annual line leak detector test:(a)not performed;(d)test report not submitted within 30 days (Mi) <br /> 26 HSC 25284.2 Annual spill containment testing not performed <br /> 27 CCR 2636 4 Annual line tightness test not performed if positive shutdown or fail safe not present <br /> 28 CCR 2661(f) Repair for tank or piping not tested for tightness within 30 days of completion of the repair (M2) <br /> 29 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) <br /> 30 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1, 1984) (MI) <br /> 31 HSC 25292.5 ELD testing not performed on a system located within 1000'of public well,or failures not repaired and retested <br /> 32 CCR 2661 Permit to repair UST system not obtained <br /> 33 HSC 25286(a) Permit to alter monitoring system not obtained <br /> 34 HSC 25298(b) Permit to temporarily close LIST system not obtained <br /> 35 HSC 25298(c) Permit to close LIST system not obtained <br /> 36 HSC 25299(a)(9) Tampering with or disabling leak detection devices or alarms <br /> 37 1 HSC 25298(a) Illegally abandoned UST system <br /> 38 1 HSC 25281.5(b)L2)_. Unburied fuel piping at marinas not visually inspected at least monthly or log not kept <br /> 39 CCR 2631.1 a UST system is not compatible with the substance stored <br /> EmTmnsy 2nLrgE systems <br /> 40CCR26 Emergency generator monitoring system not checked daily or log not kept (Mi) <br /> 41 HSC 25 Unburied fuel piping not visually inspected at least monthly or log not kept (Mj) <br /> VPH§ HSC 206UE57/01103 and 06130104) HISC 25290.1 Qnstalled on ora 07101104 <br /> Compatibility and permeability requirements:(a)UST system is not compatible with the substance stored;(b) <br /> 42 CCR 2631.1 results of the compatibility and permeability testing requirements listed in subsections CCR 2631(b)and(d)for a <br /> UST system installed after July 1,2004,were not submitted <br /> 43 HSC 25290.1(c)(1) Primary containment not liquid or vapor tight <br /> HSC 25290.2(c)(1) <br /> 44 HSC 25290.1(c)(2) Secondary containment not liquid or vapor tight <br /> HSC 222902Lc)(2) <br /> 45 HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br /> HSC 2220.2LcK3)_ <br /> 46 HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment,or the entry of liquid <br /> HSC 25290.2(d) or vapor from the primary containment into the secondary containment <br /> 47 HSC 25290.1(e) Interstitial liquid measurement method,constant vacuum,or constant pressure in the interstitial space of the UST <br /> system not maintained <br /> HSC 25290.10) UST system not tested by one of the following methods prior to use:(1)Enhanced leak detection;(2)inert gas <br /> 48 HSC 25290.2(i)--- pressure test approved by SWRCB;(3)test method deemed equivalent to(1)or(2)by the SWRCB <br /> Other violations <br /> 69 Other: <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD INSPECTOR- PHONE: UIC <br /> --24 Septic system: <br /> d&-1 2 Serves�!20 people/day <br /> RECEIV�- TITLE: 0 Receives other than sanitary waste <br /> Other disposal methods: <br /> C- <br /> Ati D[y wells/French Drains <br /> EHD 23-02-002 REV 12/09 Page 2 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.