Laserfiche WebLink
0 • <br /> San Joaquin County DIRECTOR <br /> Donna Heran, REHS <br /> PAWN . Environmental Health Department ASSISTANT DIRECTOR <br /> 600 East Main Street Laurie Cotulla,REHS <br /> Stockton, California 95202-3029 PROGRAM COORDINATORS <br /> • Carl Borgman, REHS <br /> Mike Huggins, REHS,RDI <br /> cqP Website: wwwsjgov.org/ehd Margaret Lagorio,REHS <br /> ��FOR Phone: (209)468-3420 Robert McClellon, REHS <br /> Fax: (209)464-0138 .teff Carruesco, REHS,RDI <br /> January 30,2008 Kasey Foley,REHS <br /> Service Station Systems, Inc. <br /> 680 Quinn Ave. <br /> San Jose, CA 95112 SENT VIA FAX <br /> Re: Chevron#208118, 3355 E.Hammer Ln., Stockton CA <br /> The permit(SR0053247)to reprogram the monitoring panel at the above referenced site has been <br /> approved with the following conditions. This permit replaces SR0051543 which had expired. <br /> Conditions of approval: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control <br /> District for any applicable permits. <br /> 2. Any changes shall be submitted to the San Joaquin County Environmental Health <br /> Department(EHD) for approval prior to commencing work.All new addenda supercede <br /> the previous ones. <br /> 3. All components must be certified by an independent testing organization and labeled as <br /> required by the organization. (UL,ULC,ANSI,API, ASTM,etc. See California Code of <br /> Regulations(CCR),Title 23 Chapter 16 Table B for complete list). The component must <br /> bear the appropriate mark as required by the independent testing organization. <br /> 4. Qualified service technicians must possess or work under the direct and personal <br /> supervision of an individual physically present at the work site who possesses all of the <br /> following: <br /> a. One of several permissible valid,current contractor's licenses issued by the <br /> Contractors State License Board(may be issued to the installation company),and <br /> b. All valid,current California UST certificates issued by the International Code <br /> Council(ICC),that are applicable to the work being performed, and <br /> c. A valid, current certificate of training from the manufacturer(s)of the <br /> component(s)being tested,repaired, or serviced; <br /> and <br /> d. Each person installing or testing any component must hold a certificate of <br /> training from the manufacturer of that component. <br /> 5. Before the alarm history is cleared,a current printout must be created and available for <br /> EHD inspection. Inspection may occur during the functionality test. <br /> 6. Contact Ray von Flue(468-9848)to arrange the following inspections(a 48-hour notice <br /> is required): <br /> a. EHD must witness the functionality of the monitoring system to ensure that <br /> monitoring has been restored to meet the requirements of California Code of <br /> Regulations Title 23 and the Health& Safety Code. <br />