My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3355
>
2300 - Underground Storage Tank Program
>
PR0508352
>
COMPLIANCE INFO_2008-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2021 4:50:21 PM
Creation date
6/3/2020 9:59:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2011
RECORD_ID
PR0508352
PE
2361
FACILITY_ID
FA0008044
FACILITY_NAME
CHEVRON STATION #1731*
STREET_NUMBER
3355
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12618007
CURRENT_STATUS
01
SITE_LOCATION
3355 E HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508352_3355 E HAMMER_2008-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
323
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Date: December 17,2007 Praxair Services,Inc.QA <br /> Revised by: Randy Golding Tracer light® <br /> Approved by: Randy Golding Version 6 <br /> has displaced the entire volume of the vent piping. The concentration of the tracer in the receiving container is then <br /> measured. <br /> Leak Simulation <br /> Injecting a tracer into the backfill performs a leak simulation. The leak simulation tracer is not one of the tracers used in <br /> testing the system. The migration period of the leak simulation tracer is monitored through the sampling probes. The <br /> minimum migration time required for the test is equal to the time required for the leak simulation tracer to move an <br /> acceptable distance. The minimal acceptable distance is the longest distance that the test tracer would have to travel from <br /> any leak location to the location of a sampling probe. <br /> Sample Collection <br /> Once the leak simulation migration period is determined, the inoculation and waiting period is completed and sampling <br /> can begin.Vapor samples are collected from all sampling probes. Additional vapor samples may be collected from sumps <br /> containing UST components, under dispenser containers (UDCs) and from the interstitial spaces of double walled <br /> components. <br /> Sample Analysis <br /> Samples are analyzed using an on site laboratory grade gas chromatograph(GC). The GC is calibrated using an external <br /> gas standard. Samples are analyzed by direct injection into the GC. The results are evaluated by comparison to the <br /> analytical standard. Whenever tracer is detected in the subsurface samples,blanks are run to validate the tracer detection. <br /> Spill-Bucket Testing <br /> Over-spill-buckets are tested hydro-statically. A decrease in water level indicates a leak. If leaks occur,spill bucket seals <br /> should be repaired or replaced. <br /> Reporting <br /> The findings of the Tracer Tighte ELD test and site evaluation will be summarized in a written report and sent to the client <br /> within two weeks of the completion of the fieldwork. All data acquired from probe and sump samples will be reported <br /> along with spill bucket hydra-test results. <br /> THIS INFORAtrtT10NISTHE PROPERTY OFPMYA1R SER YICa INC.. <br /> 3 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.