My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3355
>
2300 - Underground Storage Tank Program
>
PR0508352
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2021 9:09:56 AM
Creation date
6/3/2020 9:59:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0508352
PE
2361
FACILITY_ID
FA0008044
FACILITY_NAME
CHEVRON STATION #1731*
STREET_NUMBER
3355
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12618007
CURRENT_STATUS
01
SITE_LOCATION
3355 E HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508352_3355 E HAMMER_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
492
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIED PROGRAM CONSOLIDATED FO <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN- (Pae 1 of 2) <br /> TYPE OF ACTION ® 1.NEW PLAN ❑ 2.CHANGE OF INFORMATION 490-1. <br /> PLAN TYPE ® 1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 490-2. <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) 1. <br /> 01 <br /> BUSINESS NAME(Same as Facility Name or DBA) 3. <br /> Chevron Station#208118 <br /> BUSINESS SITE ADDRESS 3355 E. Hammer Lane 103 CITY Stockton 104 <br /> II. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency specified <br /> by theequipment manufacturers'instructions,or annually,whichever is more frequent.Such work must be performed by qualified personnel[23 CCR§1,631,,z63a,z63a,1,6-41 <br /> MONITORING EQUIPMENT IS SERVICED ® L ANNUALLY _._... ........9.......... ago-3a. <br /> ❑ 99.OTHER(Specify): <br /> 490-3b. <br /> II1. MONITORING LOCATIONS <br /> ® 1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN ❑ 2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED490-4. <br /> [23 CCR§2632,2634] <br /> IV.'TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) <br /> 1111 <br /> Qekij <br /> ® 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) 490-5. <br /> WITH AUDIBLE AND VISUAL ALARMS.[23 CCR§2632,2634] <br /> SECONDARY CONTAINMENT IS: ® a.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 490-6, <br /> PANEL MANUFACTURER: Veeder-Root 490-7. MODEL#: TLS-350 490-8. <br /> LEAK SENSOR MANUFACTURER: Veeder-Root 490- 490-10. <br /> ...........................................................................................__.. _. . . . . 9. MODEL#(s): 794390-409 <br /> ❑ 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).[23 CCR§2643] 490-11. <br /> PANEL MANUFACTURER 490-12. MODEL#: 490-13. <br /> IN-TANK PROBE MANUFA TURER: 490-14. MODEL#(S). 490-15. <br /> LEAK TEST FREQUENCY: ❑ a.C N .DAILY/NIGHTLY Lj c.WE 490-16. <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): 490-17. <br /> PROGRAMMED TESTS: ❑ a.0.1 g.p.h. [Ib.0.2 g.p.h. El c.OTHER(Specify): 490-18. <br /> 490-19. <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION[23 CCR§2646.1] 490-20. <br /> ...................4... ............................"...................................._..__._..................._................ <br /> ❑ WEEKLY MANUAL TANK GAUGING(MTG)[23 CCR§26451 TESTING PERIOD: ❑ a.36 HOURS ❑ 490-22. <br /> b.60 HOURS 490-21. <br /> .................................... <br /> ........ .... . <br /> .........................................................................................................._......._. .. .. . .. . . . ........ __............._._................................._ <br /> ❑ 5.TANK INTEGRITY TESTING PER[23 CCR§2643.1] ago-21 <br /> TEST FREQUENCY: <br /> ❑ b.BIENNIALLY ❑ c.OTHER(Specify): 490-24. <br /> .........................................._......._.................................._................._.._._. <br /> _.........................._a:ANNUALLY <br /> ........................................................................................................................._...............__._._._._. 490-25 <br /> 99.OTHER(Specify): 490-26" <br /> 490-27. <br /> V. PIPE''MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) I(deck all <br /> ® 1.CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE&VISUAL ALARMS. 490-28. <br /> [23 36] SECONDARY CONTAINMENT IS: ® a.DRY ❑ b.LIQUID FILLED 490-29. <br /> §2636] Q ❑ c.PRESSURIZED ❑ d.UNDER VACUUM <br /> PANEL MANUFACTURER:Veeder-Root 490-30. MODEL#: TLS-350 490-31. <br /> LEAK SENSOR MANUFACTURER: Veeder-Root 490-32. MODEL#(S): 794380-208 490-33. <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. ® a.YES ❑ b.NO 490-34. <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 490-35. <br /> 2.MECHANICAL ......................................................................................__..._......................_._. <br /> LINE LEAK DETECTOR(MELD)THAT ROUTINELY PERFORMS 3.0 g.p. LEK TESTS AND RESTRICTS OR SHUTS OFF 490-36. <br /> h. A <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.[23 CCR§2636] <br /> ML LD MANUFACTURERS : 490-31, MODEL#(S): 490-38. <br /> _........................................................ ........... <br /> .. ..... <br /> ® 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS.[23 CCR§2636] 490.-39.... <br /> ELLD MANUFACTURER(S):Veeder-Root 490-40. MODEL#(S):PLLD#848480-003 490-41. <br /> PROGRAMMED IN LINE LEAK TEST: <br /> ® a.MINIMUM MONTHLY 0.2 g.p.h. ® b.MINIMUM ANNUAL 0.]g.p.h. 49042. <br /> _....... .. :.. ... ._ .._ _ _" . . .. . <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES [Ib.NO 49043. <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 490-44. <br /> ........................................I........................................._..........................................................................................................................................I....._..._............................_...... <br /> 4.PIPE INTEGRITY TESTING. 490-45. <br /> TEST . <br /> FREQ ..... <br /> UENCY: ab.EVERY 3 YEARS c.OTHER(Specify) 490-46. <br /> _ <br /> ............................................................................. ...._. ........................._.........__..........................._....:ANNUALLYF1 [I........................................................................................................................................_..............................._.........._......_............................................... 4.... <br /> ........ <br /> 5.VISUAL PIPE MONITORING. <br /> FREQUENCY: ❑ a.DAILY ❑ b.WEEKLY ❑ C.MIN.MONTHLY&EACH TIME SYSTEM OPERATED* 490-49. <br /> _._. .*Allowed for monitorin$.of unburied emer enc enerator fuel i in onl er HSC 25281.5 3 <br /> _............................_................................................................................................................................_.............................. ........._.._........................_....... _.....1£........Y.$................................P.P....$.......... <br /> X.P.....................§.....................@25...2...._.............._.... <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA.[23 CCR§2636(a)(3)] 490-50. <br /> ........................................_......................._...._..........._..............._._............................................ <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM. 490-51. <br /> ..................__.........................--.-................._..........._.._........_............................_........................................................................................................................................................._..............................................................................__........................_............................................................................. <br /> .... <br /> .................. <br /> ....................................................................__.... <br /> ❑ <br /> 99.OTHER(Specify) 490-52. <br /> 490-53. <br />
The URL can be used to link to this page
Your browser does not support the video tag.