My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRANK WEST
>
120
>
2300 - Underground Storage Tank Program
>
PR0515365
>
COMPLIANCE INFO_1999-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2021 10:06:56 AM
Creation date
6/3/2020 9:59:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2005
RECORD_ID
PR0515365
PE
2361
FACILITY_ID
FA0012107
FACILITY_NAME
A TEICHERT & SON INC*
STREET_NUMBER
120
STREET_NAME
FRANK WEST
STREET_TYPE
CIR
City
STOCKTON
Zip
95206
APN
19342006
CURRENT_STATUS
01
SITE_LOCATION
120 FRANK WEST CIR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515365_120 FRANK WEST_1999-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
458
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LG 151-3 BULK FIELD-CONSTRUCTED ...D PIPING MONITORING AND COMPlhttptww.swrcb.ca.gov/—cwphome/ust/Ig- <br /> that is capable of detecting release rates of 0.1 gph with at least a 95%probability of detection and not <br /> more than a 5% false alarm must be performed annually. <br /> 4. Monthly monitoring using a third-party certified equipment that is capable of detecting release rates <br /> of larger than 2 gph but equal to or less than 3 gph with at least a 95%probability of detection and <br /> not more than a 5% false alarm. In addition to monthly monitoring, groundwater monitoring <br /> performed monthly in accordance with Section 2648, as approved by the local agency, must also be <br /> performed. <br /> 5. A third-party certified continuous vapor monitoring or monthly ground water monitoring in <br /> accordance with Section 2647 or 2648, and an annual tank tightness test that is capable of detecting <br /> release rates of 0.1 gph with at least a 95%probability of detection and not more than a 5% false alarm <br /> annually. <br /> 6. Quarterly monitoring using a third-party certified test method that is capable of detecting release <br /> rates of 0.2 gph with at least a 95%probability of detection and not more than a 5%false alarm. <br /> Monthly groundwater monitoring in accordance with Section 2648 and as approved by the local <br /> agency must also be performed. <br /> 7. Monthly monitoring using a third-party certified equipment/test method that is capable of detecting <br /> release rates of 1-2 gph (inclusive)with at least a 95%probability of detection and not more than a 5% <br /> false alarm. In addition to monthly monitoring, a test method that is capable of detecting release rate of <br /> 0.2 gph with at least a 95% probability of detection and not more than a 5% false alarm must be <br /> performed semi-annually. <br /> 8. Monthly monitoring using a third-party certified equipment/test method that is capable of detecting <br /> release rates of 1-2 gph (inclusive) with at least a 95%probability of detection and not more than a 5% <br /> false alarm. In addition to monthly monitoring, continuous vadose zone monitoring, in accordance <br /> with Section 2647, must also be performed <br /> 9. Monthly monitoring using a third-party certified equipment/test method that is capable of detecting <br /> release rates of larger than 0.3 gph but less than 1 gph with at least a 95%probability of detection and <br /> not more than a 5%false alarm. In addition to monthly monitoring, a tank tightness test that is capable <br /> of detecting release rates of 0.1 gph with at least a 95%probability of detection and not more than a 5% <br /> false alarm musts be performed every three years. <br /> 10. Monthly monitoring using a third-party certified equipment/test method that is capable of detecting <br /> release rates of larger than 0.3 gph but less than 1 gph with at least a 95%probability of detection and <br /> not more than a 5% false alarm. In addition to monthly monitoring, a test method that is capable of <br /> detecting release rates of 0.2 gph with at least a 95%probability of detection and not more than a 5% <br /> false alarm must be performed annually. <br /> 2 of 3 1/10/00 3:24 PM <br />