COMPLIANCE INFO_1999-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRANK WEST
>
120
>
2300 - Underground Storage Tank Program
>
PR0515365
>
COMPLIANCE INFO_1999-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2021 10:06:56 AM
Creation date
6/3/2020 9:59:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2005
RECORD_ID
PR0515365
PE
2361
FACILITY_ID
FA0012107
FACILITY_NAME
A TEICHERT & SON INC*
STREET_NUMBER
120
STREET_NAME
FRANK WEST
STREET_TYPE
CIR
City
STOCKTON
Zip
95206
APN
19342006
CURRENT_STATUS
01
SITE_LOCATION
120 FRANK WEST CIR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515365_120 FRANK WEST_1999-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
458
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTIO91 ♦ Secondary Contain ent ping System Components <br /> d. If solvent is used to clean bonding surfaces, allow 3. One r wrench <br /> the cleaner to evaporate. Then apply adhesive to <br /> all bonding surfaces, and insert the nipple into the For installing saddles,the following equipment is recom- <br /> line by lifting the line or moving it to one side. mended: <br /> Pushing the pipe back into the line will push the <br /> nipple into the bell. Make certain that all tapers 1. Sanding equipment <br /> are tightly locked. Be careful not to cock the joint. <br /> a. power sander with rough surface sanding disc(flex- <br /> 1.8.4 Leaking Joints ible pad with 40 grit or less disc), or <br /> Any adhesive-bonded joints that leak during pressure test- b. hand file (coarse) <br /> ing MUST BE REMOVED AND REPLACED. Follow the <br /> procedures shown for Fig. 1.8.6 using two sleeve couplings 2. Fine-tooth circular hole saw with pilot drill <br /> and pipe nipple. <br /> 3. Hose clamps or Band-It(2)banding tool large enough to <br /> Upon completing any necessary repairs to the piping sys- secure saddles to pipe. (If banding is used, the Band-It <br /> tem, follow the proper testing sequence to verify the sys- banding tool is preferred,because this tool does not <br /> tem's integrity. leave slack in the band when the tool is removed. Two <br /> Band-It tools are recommended so that the saddle can <br /> PART TWO •SECONDARY CONTAINMENT PIPING be pulled down uniformly. Use%" (19 mm)banding. <br /> INTRODUCTION Section 5-Cutting and Tapering(cutting) <br /> Before beginning any installation, it is important that Section 6-Installation (piping layout and trench design; <br /> all crew members read and be familiar with the instal- adhesive mixing and curing) <br /> lation procedures described in this manual. <br /> � rAINMENT PIPING SYSTEM <br /> r� � <br /> F <br /> The secondary containment piping system is designed for )��@� <br /> use with RED THREAD IIA product pipe. The secondary 110rofh <br /> containment system consists of the next larger size pipe �� Containment Pipe <br /> and special two-piece fittings. Smith Fiberglass Products "RIN <br /> rV <br /> also offers a patented(1)telescoping containment pipe sys- fiberglass Products secondary containment piping <br /> tem that allows 100%inspection of primary piping(refer ��es are as follows: <br /> to Part Three). <br /> Containment Pipe Size For Product Pipe Size <br /> Many of the procedures used for installing product 3" 75 mm 2" 50,inni° <br /> pipe and fittings are also used for installing secondary 4" 100 mm " 3" 75 rnm <br /> containment pipe and fittings. Refer to Part One for 6"(3) 150 mm 4" 100 mm <br /> installation instructions for product pipe and fittings <br /> and to Bulletin No. F6600 for tapering tool operating 2.1.2 Secondary Containment Fittings <br /> instructions. <br /> Available secondary containment fittings are tees, 90°el- <br /> Following are useful sections of Part One: bows, 45°elbows, couplings, nipples,termination fittings <br /> (with or without%"NPT threaded outlet), and saddles <br /> Section 1 -Storage and Handling (belled or with NPT threaded outlets). <br /> Section 2-Layout and Preparation 2.1.3 Adhesive for Secondary Containment Piping <br /> Section 3-Tool and Equipment List For petroleum products, alcohols, and alcohol/gasoline <br /> mixtures, use DS-8000 or DS-7000 series adhesive for in- <br /> Note: For installation of bolts, use one of the following: stalling secondary containment piping systems. When <br /> joining secondary containment pipe-to-fittings and fit- <br /> 1. X"variable impact wrench with X" socket tings-to-fittings, fiberglass filler must be added to the <br /> adhesive to ensure optimum performance of this type <br /> 2. X"variable speed drill motor with X"socket of bonded joint. Filler must be ordered from Smith <br /> Fiberglass Products. Due to the quantity of adhesive re- <br /> (1)U.S.Patent No.4,805,444 (3) Note: 6"(150 mm)secondary containment pipe is not UL Listed. <br /> (2) Band-It Banding Tool available from Band-It Idex,Inc.,P.O.Box 16307, <br /> 4799 Dahlia St.,Denver,CO 80216,303-320-4555. <br /> RED THREAD IIA Pipe br Fittings 21 <br />
The URL can be used to link to this page
Your browser does not support the video tag.