Laserfiche WebLink
Nominal <br />Nominal <br />Nominal <br />Nominal Wall <br />Nominal I <br />psi @ 751 <br />Mill Test <br />External Pressure <br />Random <br />Pipe Size"" <br />I.D. <br />O.D. <br />Thickness <br />Weight <br />Pressure -Temp. <br />Pressure <br />Max. Rating (psig/MPa) <br />Lenggths <br />(in.) <br />(in./mm) <br />(in./mm) <br />(in./mm) <br />(lbs: ft./kg-m) <br />Max. Rating <br />(psig) <br />75°F/24°C 150°F/66°C <br />(ft. ?Ml) <br />2 <br />2.235 <br />2.375 <br />0.070 <br />0.4 <br />250 psig@ 150° F <br />375 <br />88 <br />79 <br />15 <br />56.77 <br />60.33 <br />1.78 <br />0.60 <br />1.72 MPa @ 66.5°C <br />2.59 <br />.61 <br />.54 <br />or <br />3 <br />3.360 <br />3.500 <br />0.070 <br />0.8 <br />175 psig @ 150° F <br />300 <br />29 <br />24 <br />22-25 <br />85.34 <br />88. 1 <br />1.78 <br />1 1.19 <br />1.21 MPa @ 66.5`C <br />2.07 <br />.20 <br />.17 <br />2' ix 3, 2" & 3" <br />4 <br />4.360 <br />1 <br />4.530 <br />0.085 <br />1.0 <br />125 psig @ 150° F <br />265 <br />34 <br />30 <br />5.0 <br />or <br />13,03017) <br />110.74 <br />115.06 <br />2.16 <br />1.49 <br />0.86 MPa @ 66.5°C <br />1.83 <br />.23 <br />.21 <br />6.7- 7.6 <br />A <br />Nominal <br />Pipe Size <br />inches <br />PROPERTY <br />2", 3", 4" RED THREAD® IIA Pipe <br />4" <br />psi @ 751 <br />MPa @ 24`C psi @ 150°F <br />MPa @ 66°C <br />Axial Tensile (ASTM D2105) <br />in <br />21.3 <br />33.5 <br />Ultimate Stress <br />15,200 <br />104.8 13,300 <br />91.7 <br />Design Stress <br />3,800 <br />26.2 3,325 <br />22.9 <br />Modulus of Elasticity <br />1.80 x 106 <br />12411 1.4 x 106 <br />9653 <br />Axial Compression (ASTM D695) <br />Ultimate Stress <br />33,300 <br />230.0 25,600 <br />177.0 <br />Design Stress <br />8,300 <br />1.26 x 106 <br />57.2 6,400 <br />8687 x 106 <br />44.1 <br />6136 <br />Modulus of Elasticity <br />.89 <br />Beam Bending (SFPTM) <br />Ultimate Stress <br />23,000 <br />159.0 NA <br />NA <br />Design Stress(" <br />2,900 <br />20.0 1,800 <br />12.4 <br />Modulus of Elasticity <br />2.18 x 106 <br />15031 1.79 x 106 <br />12342 <br />(Long Term per ASTM D2925) <br />Hydrostatic Burst (ASTM D1599) <br />Ultimate Hoop <br />Tensile Stress <br />35,000 <br />241.0 41,000 <br />283.0 <br />Hydrostatic Design (ASTM D2992) <br />2" & 3" <br />2' ix 3, 2" & 3" <br />2" & 3" <br />Procedure A <br />9,410"6) <br />64.9 7,400"8) <br />51'1' <br />Cyclic 150 x 106 <br />4" <br />4" 4" <br />4" <br />Cycles <br />13,03017) <br />89.8 10,450 <br />72.1 <br />Coefficient of Linear <br />0.88 x 106 in./in./°F <br />Thermal Expansion (SFPTM) <br />1.58 x 10'mm/mm/^C <br />Specific Gravity <br />1.8 <br />Flow Factor <br />Hazen -Williams Coefficient <br />150 <br />Bending Radius, Minimum <br />Nominal <br />Pipe Size <br />inches <br />2" <br />3" <br />4" <br />Ft. <br />70 <br />110 <br />140 <br />in <br />21.3 <br />33.5 <br />42.7 <br />(1) All values except pressure -temperature <br />maximum rating are nominal values. <br />Tolerances or maximum/minimum limits <br />can be obtained from Smith Fiberglass <br />Products Inc. <br />(2) All sizes can accept full vacuum pressures at <br />maximum temperature ratings. <br />(3) UL Listed 5" secondary containment piping <br />and Non -UL Listed 6" secondary <br />containment piping are also available from <br />Smith Fiberglass Products Inc. <br />(4) Ultimate and allowable design stresses are <br />based on minimum reinforced wall <br />thickness. Pipe is manufactured in' <br />compliance with ASTM D2996. <br />(5) Design bending stress is 1/8 of ultimate to <br />account for combined stress (i.e. bending <br />and pressure). <br />(6) Design stress is based on long term cyclic <br />fatigue data using ASTM D2992 test <br />method. However, all testing is not <br />complete at time of printing. <br />(7) For RED THREAD IIA pipe the hydrostatic <br />cyclic design stress was determined at 150° <br />and 200°F, per ASTM D2992 Procedure A. <br />Based on this data, the extrapolated value at <br />75°F is 13,030 psi. <br />(8) For RED THREAD IIA pipe the hydrostatic <br />cyclic design stress was determined at 75° <br />and 2001, per ASTM D2992 Procedure A. <br />Based on this data, the extrapolated value at <br />1501 is 7,400 psi. <br />It is the policy of Smith Fiberglass Products to improve its products continually. In accordance with that policy, the right is reserved to make changes in specifications, <br />descriptions and illustrative material contained in this manual as conditions warrant. The information contained herein is general in nature and is not intended to express any <br />warranty of any type whatsoever nor shall any be implied. <br />MEMBER <br />P www "s, <br />"Little <br />;-A3477Wschitaj1] <br />11 <br />SMITH FIBERGLASS PRODUCTS INC. <br />A Subsidiary of A.O. Smith Corporation <br />2700 West 65th Street • Little Rock, Arkansas 72209-8592 • Telephone (501)568-4010 • FAX (501)568-4465 <br />URL: http://www.aosmith.com/sfp <br />©Copyright 1992 Smith Fiberglass Products Inc. <br />8 and TM Trademarks of Smith Fiberglass Products Inc. PRINTED IN U.S.A. 7.5M1196 <br />C-1--, <br />