Laserfiche WebLink
Model No. <br />Single/ <br />1 or <br />Soleno <br />Suction Pumps <br />Twin <br />Prod s <br />Max. GPM (LPM)* <br />Motors)** <br />Valves <br />Hose(s) W- <br />9152A <br />Single <br />1 <br />Up to 15 (57) <br />(1) 1/2 HP <br />None <br />(1) 3/4" x 12'(1.9 cm x 3.7 m) <br />9152ATW1 <br />Twin <br />1 <br />Up to 15 (57) <br />(1) 3/4 HP <br />3/4" (1.9 cm) <br />(2) 3/4" x 12'(1.9 cm x 3.7 m) <br />9152ATW2 <br />Twin <br />2 <br />Up to 15 (57) <br />(2) 1/2 HP <br />None <br />(2) 3/4" x 12'(1.9 cm x 3.7 m) <br />9153A <br />Single <br />1 <br />Up to 22 (83) <br />(1) 3/4 HP <br />None <br />(1) 1" x 12' (2.5 cm x 3.7 m) <br />9153ATWlM <br />Twin <br />1 <br />Up to 18 (68) <br />(2) 3/4 HP <br />None <br />(2) 1" x 12' (2.5 cm x 3.7 m) <br />9153ATW2 <br />Twin <br />2 <br />Up to 22 (83) <br />(2) 3/4 HP <br />None <br />(2) 1" x 12' (2.5 cm x 3.7 m) <br />9153AHC <br />Single <br />1 <br />Up to 26 (98) <br />(2) 1/2 HP <br />None <br />(1) 1" x 12' (2.5 cm x 3.7 m) <br />Remote Dispensers <br />9152AX <br />Single <br />1 <br />Up to 15 (57) <br />None <br />3/4" (1.9 cm) <br />(1) 3/4" x 12'(1.9 cm x 3.7 m) <br />9152AXTW1 <br />Twin <br />1 <br />Up to 15 (57) <br />None <br />3/4" (1.9 cm) <br />(2) 3/4" x 12'(1.9 cm x 3.7 m) <br />9152AXTW2 <br />Twin <br />2 <br />Up to 15 (57) <br />None <br />3/4" (1.9 cm) <br />(2) 3/4" x 12'(1.9 cm x 3.7 m) <br />9153AX <br />Single <br />1 <br />Up to 22 (83) <br />None <br />1" (2.5 cm) <br />(1) 1" x 12' (2.5 cm x 3.7 m) <br />9153AXTW1 <br />Twin <br />1 <br />Up to 22 (83) <br />None <br />1" (2.5 cm) <br />(2) 1" x 12'_ (2.5 cm x 3.7 m) <br />9153AXTW2 <br />Twin <br />2 <br />Up to 22 (83) <br />None <br />1" (2.5 cm) <br />(2) 1" x 12' (2.5 cm x 3.7 m) <br />Note: GPM rates shown are all maximum test rates. Actual delivery rates will vary depending upon the installation conditions, product dispensed, added <br />accessories, and if applicable, size of submersible pump. For single product twin <br />pumps (9152AXTW1) flow rates are <br />given up to 15 GPM (56.6 LPM) for <br />both hoses combined or for one operating alone. Flow rates for 9153ATWlM are up to 18 GPM (68.1 LPM) for both hoses <br />combined or one operating <br />alone. Maximum flow rates for suction pumps for 50 Hz operation will be 83% of rate shown. <br />" For suction pump applications requiring extended fueling times, or heavy period fueling, select models with continuous duty motors. <br />Actual Dimensions <br />Single: 52 5/8" H x 2513/16" W x 183/6" D (133.7 cm x 65.6 cm x 46.7 cm) <br />Twin: 52 5/8" H x 291/16" W x 183/6" D (133.7 cm x 73.8 cm x 46.7 cm) <br />Packaging Dimensions <br />57" H x 34" W x 25" D (144.8 cm x 86.4 cm x 144.8 cm) <br />SPECIFICATIONS <br />Registers -Non -computer mechanical type <br />(no dollars and cents) with power reset <br />interlock. Show gallons and tenths or litres <br />and tenths. Four -digit readout: maximum <br />999.9 gallons or litres. Displays on both front <br />and back of cabinets. <br />Totalizer -readable from the back without <br />opening the cabinet. Non -reset. Reads up <br />to 999999.9 and rolls over. <br />Pump: Quiet, efficient, gear pump. Air <br />eliminator built into pump casting. <br />Meter Type: Three piston, positive <br />displacement. Tested and calibrated for <br />accuracy at any speed or pressure. <br />Standard Cabinet Finish: Top and sides <br />are painted black. Black polycarbonate <br />bezel. Front and back panels are painted <br />white or specify color. <br />Voltage and Frequency: 115/230VAC, <br />60 Hz. 50 Hz available extra cost. <br />Note: Model 9153HC <br />requires 230VAC <br />Motor Ratings: 1/3 hp intermittent duty; <br />1/2 hp and 3/4 hp, continuous duty <br />Suction Connection: 11/2" NPT. Unions <br />provided. <br />Maximum Working Pressure: 50 psi <br />UL listed <br />OPTIONS AND ACCESSORIES <br />Automatic Nozzles: Standard or High <br />Flow. Nozzle spouts for unleaded or leaded <br />gasoline, diesel, or kerosene. . <br />Lights: Fluorescent. Illuminated product <br />panels and register areas. On-off switch <br />standard. <br />Pulser: Type and ration as specified for <br />the application. <br />Switch Detect: As required to equip the unit <br />for use in card systems. <br />Special Lengths of Hose: Longer or shorter <br />than standard 12' to meet special needs at <br />extra cost. <br />Swivels: For easier, more convenient hose <br />handling. <br />Internal Hose Retractor: A compact way <br />to keep hoses out of trouble. <br />High Hose Retractor: High post -mounted <br />type with enclosed spring return reel and <br />nylon cable assembly. Keeps hose up and <br />out of the way to reduce runover damage. <br />Filters: Internal standard flow or high flow <br />filters available. Also, internal and external <br />high flow filters with hydrosorb elements. <br />Internal filters not available on TW2 pumps, <br />twin pumps with slowdown valve option, or <br />9153AHC pumps. <br />Vertical Check Valves: For installation on <br />suction line to prevent backflow from the <br />pump. Not for remote dispensers and sub- <br />mersible pump systems. Sizes for standard <br />Vh" line, and for oversize 2" line. <br />High/Low Slowdown Valve: Reduces <br />delivery to a slow flow for accurate preset <br />shut-off. 1" valve available for high gallon- <br />age models. <br />Vapor Recovery System: Includes high <br />hose retractor, special nozzle bootand hanger, <br />automatic nozzle, coaxial hose, vapor valve, <br />and connection hose with swivel. <br />Vapor Recovery Kit: Includes special <br />nozzle boot and hanger only. <br />Satellite Piping: Available on all remote <br />dispensers. <br />Stainless Steel Panels: Three choices: <br />-All Stainless steel <br />-Stainless steel front and back panels <br />-Stainless steel top and sides <br />Gasboy International, Inc. • P.O. Box 309, Lansdale, PA 19446-0309 - Phone 215-855-4631 - Fax # 215-855-0341 <br />Canada, Fax # 613-475-1145 • Germany, Fax # 49-881-922099 - Scotland, Fax # 44 -592 -771095 -- <br />South Africa, Fax # 27-11-462-1942 <br />Shear Valve: Required for remote dis- <br />penser installations with submersible pump. <br />It stops the flow of product if the dispenser is <br />damaged and the submersible pump continues <br />operating. <br />Electrical Keyrol Systems: Control and <br />record fuel usage through individual lock - <br />totalizers. Master console is available with <br />a minimum of ten lock -totalizers and a <br />maximum of 50 in increments of five or ten. <br />Unlimited auxiliary slave console capability <br />allows expansion to any practical size. <br />Consoles are easily expandable at any time. <br />Electrical Keytrol is factory installed on top <br />of the pump or dispenser. Optionally, may <br />be mounted remote. Master console and one <br />auxiliary console may be pump mounted. Pump <br />mount is not available on lighted models. <br />To order, please specify: <br />1. Model Number <br />2. Product designations for brand panels <br />3. Any options or accessories desired <br />4. Automatic nozzle type and spout; pulser <br />type, when applicable <br />Prices and specifications subject to change <br />without notice. <br />Warning <br />Failure to follew t ese instructions may result in property damage, <br />personal injury, or loss of life. Gasboy products must be installed <br />by a qualified installer and used in conformance with all building, <br />fire, and environmental codes and other safety requirements <br />applicable to their installation and use, including, but not limited <br />to, NFPA 30, NFPA 30A, and NFPA 70. This Product is only part <br />of a fuel dispensing system, and additional equipment and <br />accessories, such as, but not limited to, breakaway connectors, <br />shear valves, pressure regulators, and other safety devices may <br />be necessary to meet the applicable codes. Qualified installers <br />shall be familiar with fuel system installations under the above <br />stated building, fire, and environmental codes and other safety <br />requirements required for the particular type of installation Gasbov <br />dispensers shall not be used for the direct fueling of aircraft <br />without filters, separators and other equipment necessary, to <br />ensure product purity. All sales subject to Gasboy standard warranty. <br />GASBOYV <br />A TOKHEIM SUBSIDIARY <br />© 1997 Gasboy International, Inc. <br />A Tokheim Subsidiary <br />Printed in U.S.A Bulletin No. SL916OR • Rev -1/97 <br />M <br />