My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRANK WEST
>
120
>
2300 - Underground Storage Tank Program
>
PR0515365
>
COMPLIANCE INFO_1999-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2021 10:06:56 AM
Creation date
6/3/2020 9:59:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2005
RECORD_ID
PR0515365
PE
2361
FACILITY_ID
FA0012107
FACILITY_NAME
A TEICHERT & SON INC*
STREET_NUMBER
120
STREET_NAME
FRANK WEST
STREET_TYPE
CIR
City
STOCKTON
Zip
95206
APN
19342006
CURRENT_STATUS
01
SITE_LOCATION
120 FRANK WEST CIR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515365_120 FRANK WEST_1999-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
458
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A& Ask <br /> INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> r n <br /> TEST DATE: 03/04/05 8501 N MOPAC EXPRESSWAY,SUITE 400 WORK ORDER NUMBER: 2234817 <br /> AUSTIN,TEXAS 78759(512)451-6334 <br /> CLIENT: TSICHSRT CONSTRUCTION SITE: TSICHERT CONSTRUCTION <br /> Tank ID: #1 1 Tank manifolded: No Bottom to top fill in inches: <br /> Product: DIESEL Vent manifolded: No Bottom to grade in inches: <br /> Capacity in gallons: 34,788 Vapor recovery manifolded: No Fill pipe length in inches: <br /> Diameter in inches: 144.00 Overfill protection: YES Fill pipe diameter in inches: <br /> Length in inches: 497 Overspill protection: YES Stage I vapor recovery: NONE <br /> Material: DW FIBERG Installed: ATG Stage II vapor recovery: NONE <br /> CP installed on: <br /> COMMENTS <br /> Lines B, C High volume red jacket pumps. <br /> PSI at tank bottom: New/passed Failed/replaced New/passed Failed/replaced <br /> Fluid level in inches: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> UFT/OFT: Make: vAPORLEss VAPORLESS <br /> Fluid volume in gallons: Model: LD3000 LD3000 <br /> Tank water level in inches: S/N: unreadable 07120 <br /> Test time: NOT Open time in sec: 4.00 4.00 <br /> Number of thermisters: TESTED Holding psi: 42 40 <br /> Specific gravity: Resiliency cc: 100 150 <br /> Water table depth in inches: Test leak rate ml/m: 189.0 189.0 <br /> Determined by(method): Metering psi: 28 18 <br /> Leak rate in gph: Calib.leak in gph: 3.00 3.00 <br /> Result: Results: PASS PASS <br /> COMMENTS COMMENTS <br /> Test time: Material: DW FIBERG DW FIBERG DW FIBERG <br /> Ullage volume: Diameter(in): 2.0 3.0 3.0 <br /> Ullage pressure: Length(ft): 60.0 25.0 25.0 <br /> Results: Test psi: <br /> Bleedback cc: <br /> DATA FOR UTS-4T ONLY: Test time(min): <br /> Test 1:Start time: <br /> Time of test 1: Finish psi: NOT NOT NOT NOT <br /> Temperature: NOT Vol change cc: <br /> TESTED TESTED TESTED TESTED <br /> cfh : TESTED <br /> Flow rate Test 2:Start time: <br /> ( ) Finish psi: <br /> Time of test 2: Vol change cc: <br /> Test 3:Start time: <br /> Temperature: Finish psi: <br /> Flow rate(cfh): Vol change cc: <br /> Time of test 3: Final gph: <br /> Temperature: Result: <br /> Flow rate(cfh): Pump type: PRESSURE PRESSURE PRESSURE PRESSURE <br /> COMMENTS Pump make: RED JACKET RED JACKET RED JACKET <br /> COMMENTS Impact Valves Operational: YES <br /> Printed 08/08/2005 15:54 KOHLMEYER <br />
The URL can be used to link to this page
Your browser does not support the video tag.