Laserfiche WebLink
LINE LEAW DETECTOR (LLD) M <br />TEST DATE: September 11, 2014 <br />Al. FACILITY A2. OWNER <br />Name Teichert Mobile Equipment Name Teichert ConstructionSEP 2 5 2014 <br />Address 120 Frank Circle, Stockton, CA 95206 Address P.O. Box 15002, Sacramento, CA 95851 <br />Phone# 916-366-8631 Phone# 916-386-3767 ENVIRONMENTAL HEALTH <br />Contact Steve Schamaun Contact Steve Schamaun <br />A3. C U P A <br />1 <br />Product contained <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />Leak detector make/model <br />Name <br />Walton Engineering, Inc. <br />Address <br />1868 E. Hazelton Avenue, Stockton, CA 95202 <br />19 <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />August 26, 2014 <br />Pump pressure (psi) <br />Lic # <br />617238 A, B, Haz <br />Inspector <br />Stacy Rivera <br />40 <br />Contact <br />Veronica Freitas <br />Phone # <br />209-468-8257 <br />TEST RESULT <br />Phone # <br />916-373-1166 <br />I. LINE LEAK DETECTOR TEST RESULTS <br />I est touloment used: <br />Tank number <br />1 <br />Product contained <br />C-1 Diesel <br />Leak Detector Type <br />ELLD <br />Leak detector make/model <br />0848480.001 <br />Serial number <br />H96085 <br />Functional Element Holding (psi) <br />19 <br />Resiliency (ml) <br />65 <br />Test leak rate (gph) <br />3.00 <br />Pump pressure (psi) <br />40 <br />Metering pressure (psi) <br />0 <br />Pressure Restriction Reduction (psi) <br />40 <br />Length of Restriction Test (seconds) <br />0 <br />Full Flow Opening time (seconds) <br />0 <br />TEST RESULT <br />PASS <br />Tank number <br />Product contained <br />Leak Detector Type <br />Leak detector make/model <br />Serial number <br />Functional Element Holding (psi) <br />Resiliency (mi) <br />Test leak rate (gph) <br />Pump pressure (psi) <br />Metering pressure (psi) <br />Pressure Restriction Reduction (psi) <br />Length of Restriction Test (seconds) <br />Full Flow Opening time (seconds) <br />TEST RESULT <br />J. COMMENTS: <br />I/aporless VMI LDT-890 <br />2 <br />C-2 Gasoline - 87 <br />ELLD <br />0848480-001 <br />270880 <br />20 <br />55 <br />3.00 <br />40 <br />0 <br />40 <br />0 <br />0 <br />PASS <br />7 <br />Diesel 5 HP <br />ELLD <br />0848480001 <br />114012 <br />20 <br />100 <br />3.00 <br />36 <br />0 <br />36 <br />0 <br />0 <br />PASS <br />WALTON <br />Signature: <br />ENGINEERING, INC. <br />Technician: Jessie Wadkins / B35391 5307886 -UT Date: September 11, 2014 <br />