My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRANK WEST
>
120
>
2300 - Underground Storage Tank Program
>
PR0515365
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/11/2023 3:11:49 PM
Creation date
6/3/2020 9:59:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0515365
PE
2361
FACILITY_ID
FA0012107
FACILITY_NAME
A TEICHERT & SON INC*
STREET_NUMBER
120
STREET_NAME
FRANK WEST
STREET_TYPE
CIR
City
STOCKTON
Zip
95206
APN
19342006
CURRENT_STATUS
01
SITE_LOCATION
120 FRANK WEST CIR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515365_120 FRANK WEST_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 5. SECO1f1..4,,VYP`WE-V1,SjV-hTG <br />Test Method Developed By: X Piping Manufacturer 0 Industry Standard 0 Profession ffyirgr <br />2014 <br />0 Other (Specify) <br />Test Method Used: X Pressure 0 Vacuum 0 Hyd EWIRONMENTAI <br />0 Other (Specify) HEALTH man <br />Test Equipment Used: Pressure Gauge <br />-En <br />Equipment Resolution: 0-15 PSI <br /># 4 <br />Piping Run # I <br />Piping Run # 2 <br />Piping Run # 3 <br />Piping Run <br />Piping Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Piping Manufacturer: <br />Smith <br />Smith <br />Smith <br />Smith <br />Piping Diameter:— <br />4" <br />4" <br />311 <br />3" <br />Length of Piping Run: <br />30' <br />30' <br />50, <br />40' <br />Product Stored: <br />Diesel <br />Diesel <br />Diesel <br />Gas <br />Method and location of <br />Test boot <br />Test boot <br />Test boot <br />Test boot <br />piping -run isolation: <br />Wait time between applying <br />pressure/vacuum/water and <br />5 min <br />5 min <br />5 min <br />5 min <br />starting test. <br />Test Start Time: <br />8:30 <br />8:15 <br />Initial Reading (RO: <br />5 PSI <br />5 PSI <br />5 PSI <br />5 PSI <br />Test End Time: <br />9:30 <br />9:15 <br />Final Reading (RF): <br />5 PSI <br />5 PSI <br />5 PSI <br />5 PSI <br />Test Duration: <br />I Hour <br />I Hour <br />I Hour <br />I Hour <br />Change in Reading (RF -R,): <br />0 <br />0 <br />Pass/Fail Threshold or <br />0 drop <br />0 drop <br />0 drop <br />0 drop <br />Criteria: <br />Test Result: <br />0 Pass 0 Fail <br />13 Pass El Fail <br />x Pass 0 Fail <br />x Pass 11 Faii <br />Comments — (include information on repairs made prior to testing, and recommendedfollow-upforfailed tests) <br />Line I unable to test due to hole in test boot at load rack. (west sump) <br />Line 2 unable to test due to tear in boot near Schrader valve at the load rack (west sump) <br />*Please see attached supplemental testform for line test <br />
The URL can be used to link to this page
Your browser does not support the video tag.