My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1330
>
2300 - Underground Storage Tank Program
>
PR0515864
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 10:44:40 AM
Creation date
6/3/2020 10:00:02 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0515864
PE
2361
FACILITY_ID
FA0012355
FACILITY_NAME
A&A GAS FOOD MART
STREET_NUMBER
1330
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120053
CURRENT_STATUS
01
SITE_LOCATION
1330 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515864_1330 E YOSEMITE_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
486
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11 <br />E <br />SWRCB, January 2002 Page _ of <br />tesiMe,a;odb�,;Iioped i'.. UDC Manufacturer C Industry Standard Professional Engineer <br />C Other (Spec6) <br />Test Method Used: 0 Pressure El Vacuum �eHydrostatic <br />0 Other (Specify) <br />Test Equipment Used: (PW L) T G — Equipment Resolution: 0. 0001 <br />UDC Manufacturer: <br />UDC Material: <br />UDC Dep#�: <br />Height from UDC Bottom to <br />Lo est Electrical Penetration: <br />Condition of UDC prior to <br />testinR: <br />1,11 Portion of UDC Tested <br />Does turbine shut down when I' <br />LJDC sensor detects.liquid (both <br />%Yes 0 No <br />. RR x R1) <br />Ills <br />system programmed for fail- <br />Y' .R 0 No 0" <br />§(Yes El No El NA <br />safe shutdown9. <br />Was fail-safe verified to be <br />A -Yes ElIIA <br />operational?* <br />Wait time between applying <br />pressure/vacuum/water and <br />Test End Time: <br />Test Duration:— <br />Was sensor removed for testing? <br />Yes 0 No 0 NA <br />jj Q, Nil <br />-gYes 0 No 0 NA <br />IM11.0,110 RUN'S <br />If the answer to anjLaLtg_Zuestions indicated with an <br />asterisk (*) is "NO" or "NA". the entire UDC must be tested. (See SVvrRCB LG- 160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.