Laserfiche WebLink
0 SAN JOAQUIN COUNTY 0 <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd/unitiii.htmi <br />CONTINUATION FORM <br />Page: 3 of 3 <br />OFFICIAL INSPECTION REPORT <br />Date: 06/23/10 <br />Facility Address: 1330 Yosemite Avenue, Manteca <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS 1, CLASS II, or MINOR -Notice to Com <br />Monitoring Certification Inspection Report. <br />3. Facility's tank form is not current. The overfill prevention information isnot correct. New form was <br />provided and the owner updated the information. A new facility form was also filled out. <br />4. Facility does not have a current financial responsibility certification. This is a violation of Health and <br />Safety Code 25292.2. A new financial responsibility certification was provided and the owner updated <br />the information. This is a repeat violation. This is a annual requirement. <br />11. The liquid sensor in the 91 turbine sump was nct located at the lowest point. The 87 annular sensor <br />is 7 inches short thus not located at the lowest point. Pursuant to California Code of Regulation section <br />2630(d) the sensors will not detect a leak at the earliest opportunity. A new sensor (model number <br />794390-409, serial number 799144) was installed and was placed in the correct location. A permit must <br />be obtain from the EHD by the next business day. <br />12. Liquid sensor at dispenser number 1/ 2 failed the hydrostatic test. Pursuant to H&S code 25291(b) <br />a facility must have a monitoring system capable of detecting a leak from the primary to the secondary <br />containment. A new sensor was installed ( Model number 794380-322, serial number 163361). Service <br />Technician Lupe Sanchez, ICC # 5250451 - UT. A permit must be obtained from this office by the next s <br />15. A secondary containment testing was performed on November 25. 2008, and the Regular fill sump <br />failed the test. A follow up letter for the repair and retest was sent on March 6, 2009 and since then no <br />action has been taken. Secondary containment for the UST system is not tight. Immediately, have the <br />UST system investigated, repaired and retested by a properly licensed trained and certified contractor <br />for the secondary containment testing. A permit may be required from the Environmental Health <br />Department. <br />24, 25, 26. Last monitoring certification leak detector test and the spill bucket test for the facility was <br />performed on November 25, 2008. Facility is 19 months late for a monitoring certification, leak detector <br />test and spill bucket test. This is a annual requirement. A monitoring certification leak detector test and <br />spill bucket test was performed today. Avoid future occurrences. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE ($115). <br />THIS FACILITY IS SUBJECT TO REINSPECTION T A Y TIME AT EHD'S CURRENT HOURLY RATE. <br />EHD Inspector: <br />w` - N/fit� *-6$ 3 4 <br />Received y:/jiyr7�L <br />Title: <br />I <br />EHD 23-02-003 Rev O6/01/10 CONTINUATION FORM <br />