Laserfiche WebLink
Xerxes Corporation-Tank Accessories http://www.xerxescorp.com/noframes/tacces.htm <br /> Remvdr <br /> LetiYa G#OOiati <br /> Rti <br /> ixvei Down Xerxes DWT-II double wall tanks with the TRU-CHEK®system option are factory-filled with a brine solution in the <br /> interstice between the two tank walls.The brine also partially fills a reservoir affixed to the top of the tank.This <br /> creates a hydrostatic pressure that enables owners/users to monitor both the primary and secondary tank walls.The <br /> TRU-CHEO system provides a simple and precise method to perform a tank-tightness test.It was developed in <br /> conjunction with Dr.Robert Plunkett,Sc.D.,consulting engineer(professor emeritus),University of Minnesota. <br /> HOW CONTINOUS MONITORING WORKS: <br /> If both the inner and outer walls are tight,the reservoir level will be stable.If there is a fracture in the inner wall <br /> (Diagram A),the brine level in the reservoir will go down. <br /> The brine level in the reservoir will also go down if there is a leak in the outer wall(Diagram B). <br /> With a high water table and"wet hole"conditions(Diagram C),a leak in the outer wall will cause the brine level to go <br /> up if the height of the water table above the leak is 30%greater than the brine level above the leak. <br /> AlmmT+nk _tem up - <br /> Fractwe <br /> Quuv <br /> WaRM,� <br /> The TRU-CHEO test offers significant benefits to the owner or operator: <br /> 1. A wide range of tank sizes,including Xerxes DWT-11 tanks up to 20,000 gallons. <br /> 2. Product can be dispensed during the 95°/u/5%test. <br /> 3. No waiting time is required to start the test as long as a fill of new product does not vary more than 20 <br /> Degrees F.from the existing product temperature. <br /> The TRU-CHEK®testing meets the EPA criteria for tank-tightness testing,which states that a test must be able to detect a leak rate of 0.1 gallon per hour <br /> from any part of the tank that routinely contains product.The test has a 95%probability of detection(PD)and a 5%probability of a false alarm(PFA).In <br /> other words,the test detects leaks 95%of the time. <br /> The test must also account for the effects of thermal expansion or contraction of the product,vapor pockets,tank deformation,evaporation,condensation <br /> and the location of the water table. <br /> TRU-CHEO is capable of detecting a loss rate as small at the NFPA 329 criteria of 0,05 gallons per hour.In addition,on extended tests,TRU-CHEKO <br /> testing offers 99%PD and 1%PFA. <br /> XERXESO CORPORATION <br /> 7901 Xerxes Ave.So.,Minneapolis,MN 55431-1882 <br /> Phone:(612)887-1890 Fax:(612)887-1882 <br /> E-mail:info@xerxescor <br /> 7 of 7 05/19/2000 3:01 PM <br />