My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2000-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1234
>
2300 - Underground Storage Tank Program
>
PR0516248
>
COMPLIANCE INFO_2000-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2023 3:05:39 PM
Creation date
6/3/2020 10:00:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2005
RECORD_ID
PR0516248
PE
2361
FACILITY_ID
FA0012532
FACILITY_NAME
CHEVRON STATION #209167
STREET_NUMBER
1234
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120016
CURRENT_STATUS
01
SITE_LOCATION
1234 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0516248_1234 E YOSEMITE_2000-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
444
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Results of U.S. EPA Evaluation <br /> Automatic Tank Gauging System ( ) <br /> Continuous Statistical Leak Detect Method (CSLD) <br /> This form tells whether the automatic tank gauging system (ATGS) described below used in a <br /> CSLD mode complies with the performance requirements of the federal underground storage tank <br /> regulation. The evaluation was conducted by the equipment manufacturer or a consultant to the <br /> manufacturer according to the "Alternative Test Procedure Deemed Equivalent to EPA's." The <br /> full evaluation report also includes a form describing the method and a form summarizing the test <br /> data. <br /> Tank owners using this leak detection system should keep this form on file to prove compliance <br /> with the federal regulations. Tank owners should check with State and local agencies to make <br /> sure this form satisfies their requirements. <br /> ATO Description <br /> Name TLS Series 300/400 Monitoring Systems with Manifolded Tanks CSLD <br /> Version Number 8473 Magnetostrictive Probe <br /> Vendor Veeder-Root <br /> 125 Powder Forest Drive P.U. Box 2003 <br /> street address) <br /> Simsbury CT 06070-2003 203 651-2700 <br /> (city) sta a zip phone) <br /> Evaluation Results <br /> This ATGS, which operates in two modes depending on the specified probability of detection of <br /> a leak rate of 0.20 gallon per hour, declares a tank to be leaking when the measured leak rate <br /> exceeds a threshold designed for the chosen mode. The threshold, probability of false alarm, <br /> P(FA), and probability of detection, P(D), of detecting a leak rate of 0.20 gallon per hour, are <br /> given in the table below for the two modes of operation. <br /> Threshold Probability of False Alarm (FA) Probability of Detection (P(D)l <br /> 0.16 < 0.01% 97% <br /> 0.15 < 0.01% 99% <br /> The minimum water level (threshold) in the tank that the ATGS can detect is 0.54 inch for the <br /> magnetostrictive version #8473 probe. Note: The probe does not report water levels below <br /> 0.75 inch in normal use. <br /> The minimum change in water level that can be detected by the ATGS is 0.027 inch for the <br /> magnetostrictive version #8473 probe. <br /> Based on these results,the method 19 does 13 does not meet the federal performance standards <br /> established by the U.S. Environmental Protection Agency of 0.20 gallon per hour at P(D) of 95% <br /> and P(FA) of 5%. <br /> ATGSāCSLD Method Results Form Page 1 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.