My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1234
>
2300 - Underground Storage Tank Program
>
PR0516248
>
COMPLIANCE INFO_2006-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2023 3:40:58 PM
Creation date
6/3/2020 10:00:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2010
RECORD_ID
PR0516248
PE
2361
FACILITY_ID
FA0012532
FACILITY_NAME
CHEVRON STATION #209167
STREET_NUMBER
1234
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120016
CURRENT_STATUS
01
SITE_LOCATION
1234 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0516248_1234 E YOSEMITE_2006-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
433
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN -(Page 1 of 2) <br /> TYPE OF ACTION ® 1.NEW PLAN ❑ 2.CHANGE OF INFORMATION 490-1. <br /> PLAN TYPE ® 1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 490-2. <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): <br /> L FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) t• <br /> BUSINESS NAME(Same as Facility Name or DBA) 3. <br /> Chevron Station#209167 <br /> BUSINESS SITE ADDRESS 1234 Yosemite Ave 103. 1 CITY Manteca, CA 95336 104 <br /> II. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency specified <br /> thS e i�ment manufacturers_instructions,or annual Hfiichever is more frequent.Such work must be performed by qualified ersonneL[23 ccR§2632^2634,z63s,26411 <br /> EQUIPMENT IS SERVICED ® 1.ANNUALLY ❑ 99.OTHER(Specify): 490-3b. <br /> MONITORING E <br /> Q 490-36. <br /> III. MONITORING LOCATIONS <br /> ❑ 1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN ❑ 2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED [23 ccx§2632,2634] 490-4. <br /> IV. TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD <br /> (S) that Ix zrr <br /> 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) 490-5. <br /> WITH AUDIBLE AND VISUAL ALARMS.[23 CCR§2632,26341 <br /> SECONDARY CONTAINMENT IS: ® a.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 490-6. <br /> PANEL MANUFACTURER: Veeder-Root 490-7- MODEL#: TLS-350 490-8. <br /> LEAK SENSOR MANUFACTURER: Veeder-Root 990 MODEL#(S): Liquid Sensor Series 794380-409 490-10. <br /> _ - _..__...__ ..._.........__._........_..._.....__........... _.............. ..... - ... - -- ----._� _._.._...._.._........_.......__............................_.................................................,............__..,...........,.._..,..................... <br /> �] 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).[23 CCR§26431 490-11. <br /> PANEL MANUFACTURER 490-12. MODEL#: 490-13. <br /> IN-TANK PROBE MANUFACTURER: 490-14. MODEL#(S): 490-15. <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS b.DAILY/NIGHTLY U c.WEEKLY 490-16. <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): 490-17. <br /> PROGRAMMED TESTS: ❑ a.0.1 g.p.h. ❑ b.0.2 g.p.h. ❑ c.OTHER(Specify): 4 4W 18. <br /> __..._...._.._....................._._..............._............_______._...._-____-.-....._.____....__.._..._____-____.__..._.._____.-_............____......................._....._.........._._.._....._....__.__..___._.___._._________._.._-----.__ _..........._.................... <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION[23 CCR§2646.11 490-20. <br /> �_-_--.-_-___..... _ _ _......._.__...................-_..........................................._.__..._.._....._..._.._.._.............._.....__....__.....___._.._. ..... _ __.........................._._........_........................._......................................-____-...--...-................_............ <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)[23 CCR§26451 TESTING PERIOD: ❑ a.36 HOURS ❑ b.60 HOURS 4� z1' <br /> ._.._.... <br /> _......_.._.._..._.._......_.....__............... _......-_._._.._.............._......_..................._....._..._.._._.._.._....__.._........_._... - - .._... ------------ <br /> 0 <br /> -------- ---_.............................._.. <br /> ❑ 5.TANK INTEGRITY TESTING PER[23 CCR§2643.11 490-23. <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.BIENNIALLY ❑ c.OTHER(Specify): 490-25, <br /> _._.._.__._._....._._._.._._._................__......._......._._......_........ <br /> ..._......._........_.___..._.._._.._...._._..-_---...---..____._.._..____.___........_....._.._........................_.._..._.._....__........____.-.__...__........._.....__._____..._.._._.. <br /> Q 99.OTHER(Specify): 490-26. <br /> 490-27. <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHODS) thata`k 111 <br /> ® 1.CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE&VISUAL ALARMS. 490-28. <br /> [23 CCR SECONDARY CONTAINMENT IS: ® a.DRY ❑ b.LIQUID FILLED ® c.PRESSURIZED ❑ d.UNDER VACUUM 490-29. <br /> §26361 <br /> PANEL MANUFACTURER:Veeder-Root 490-30. MODEL#: TLS-350 490-31. <br /> LEAK SENSOR MANUFACTURER: Veeder-Root 490-32. MODEL#(S): Liquid Sensor Series 794380-208 490'33' <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. ® a.YES ❑ b.NO 490-34. <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 490-35. <br /> __...._...._.._...._..............__.__..._............._......._.._.....__....._._............_.. ----------------------------------.......___.............................__._......._.....................__...._...____..._..__-._-------------__.----------------------.._..----- - - ------_ ................ <br /> ❑ 2.MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF 490-36. <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.[23 CCR§26361 <br /> MLLD MANUFACTURER(S): 490-37. MODEL#(S): 490-38. <br /> ® 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS.[23 CCR§26361 490.39' <br /> ELLD MANUFACTURER(S):Veeder-Root 490-40. MODEL#(S):PLLD Series 848480-003 490-41. <br /> PROGRAMMED IN LINE LEAK TEST: ❑ a.MINIMUM MONTHLY 0.2 g.p.h. ❑ b.MINIMUM ANNUAL 0.1 g.p.h. 490-42. <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 490-43. <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 490-44. <br /> --------------_....___.._.__...................................................._......._.....__.._....___.__._.__._.__�__.___�_ -__.____..__..._._._._._....._.._........................_._..............___.______.................. <br /> ❑ 4.PIPE INTEGRITY TESTING. 490-45' <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.EVERY 3 YEARS C3 c.OTHER(Specify) 490-447.7. <br /> S 1f 49046. <br /> Q <br /> ❑ 5.VISUAL PIPE MONITORING. 490-48' <br /> FREQUENCY: ❑ a.DAILY ❑ b.WEEKLY ❑ C.MIN.MONTHLY&EACH TIME SYSTEM OPERATED* 490-49. <br /> ......................... *Allowedform todn&-of unMui�,emer�ency_&enactor fuelpi�in�,only er,HSC-25281.SS��................... <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA.[23 CCR§2636(a)(3)1 4.90-50. <br /> . _.. <br /> __..._._...._.._.__..._.._... ............_.........-- _ - _.. <br /> -_____ __..._ -----._. __._-_------__- ........ <br /> _-__ - - .................._.._.............. - - ----------------------------------------------------------------------------------__.._._._.......... <br /> ........ <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM. 490-5i. <br /> __ _--_-_-___-----_.._.._-_-- ... __..................._....._.._..-......_.._._.._.._.._......._.._---..._............___...._....._..._ _._.....- --------- - -- -------------_..__.........................---_------------...........-................,.... <br /> 0 99.OTHER(Specify) 490-53. <br />
The URL can be used to link to this page
Your browser does not support the video tag.