My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1234
>
2300 - Underground Storage Tank Program
>
PR0516248
>
COMPLIANCE INFO_2015-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2023 11:28:32 AM
Creation date
6/3/2020 10:00:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015-2018
RECORD_ID
PR0516248
PE
2361
FACILITY_ID
FA0012532
FACILITY_NAME
CHEVRON STATION #209167
STREET_NUMBER
1234
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120016
CURRENT_STATUS
01
SITE_LOCATION
1234 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0516248_1234 E YOSEMITE_2015-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
w <br /> Overfill Prevention Equipment Inspection <br /> .97iainknology OPW 61 and 71 Series Overfill Prevention Device Inspection <br /> Date: 10/2/2018 <br /> Customer Name: CHEVRON PRODUCTS USA <br /> Location#: 209167 <br /> Location Address: 1234 E.YOSEMITE AVE @ SPRECKLES,MANTECA CA,95336 <br /> OPW Model Number: 61-so <br /> T:1 T:2 <br /> PART 1)Proper height setting calculation <br /> Maximum Tank Volume per:Tank Chart Agallons14976 19703 <br /> Max shut off requirement for Flapper is 95% e95r 0.95 0.95 0.95 0.95 <br /> Multiply Maximum tank volume by 95% cgallons 14227.200 18717.850 <br /> Use tank chart or ATG to determine height of calculated volume D inches 105.125 105.400 <br /> Measure top of fill riser threads,or face seal adapter E inches 63.000 63.500 <br /> Tank diameter From Chart F inches 118.000 118.000 <br /> Upper Tube in tank(G) F-D=G G inches 12.875 12.600 <br /> Subtract 2 inches from upper tube in tank G-2"=K K inches 10.875 10.600 <br /> Calculated minimum upper tube length(1)K+E=I I inches 73.875 74.100 <br /> Actual measured upper tube length(Without fill <br /> J inches 74.250 82.000 <br /> adapter)(J) <br /> PART 2)Device certification criteria evaluation <br /> Criteria 1 Yes Yes <br /> Does the overfill prevention device meet the 95%requirement? <br /> -T <br /> Criteria 2 Is the Actual measured upper tube length 6.5 inches <br /> Yes <br /> or more than the fill riser?(J must be 6.5"or more Yes <br /> than E) <br /> Criteria 3 Does the overfill prevention device function as <br /> r -T <br /> equired?(Inspect the device for damage, <br /> contamination,freedom of movement, Yes Yes <br /> weakening due to wear and corrosion) <br /> PART 3)Device Certification PASS/FAIL <br /> Technician certifies that the device is operationally <br /> compliant. If the response to Criteria 1,2 and 3 above Pass Pass <br /> are YES <br /> Comments: <br /> � e <br /> ; $�L,it P <br /> Signature of + �,� <br /> Technician: "I$- Date: 10/2/2018 <br /> Edwin Pineda <br /> WO: NW1-2337835 <br />
The URL can be used to link to this page
Your browser does not support the video tag.