My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3304
>
2300 - Underground Storage Tank Program
>
PR0516354
>
COMPLIANCE INFO_2002-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2021 11:44:26 AM
Creation date
6/3/2020 10:00:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2007
RECORD_ID
PR0516354
PE
2361
FACILITY_ID
FA0012437
FACILITY_NAME
CHEVRON 352324
STREET_NUMBER
3304
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
07120013
CURRENT_STATUS
01
SITE_LOCATION
3304 W HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0516354_3304 W HAMMER_2002-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
349
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM yY1 <br /> TANKS <br /> UNDERGROUND STORAGE TANKS-TANK PAGE 1 <br /> (two pages per tank) <br /> Page _ of <br /> TYPE OF ACTION NEW SITE PERMIT ❑ 4. AMENDED PERMIT ❑ S. CHANGE OF INFORMATION) ❑ 6. TEMPORARY SITE CLOSURE <br /> (Check one item onty) ❑ 7. PERMANENTLY CLOSED ON SITE <br /> ❑3.RENEWAL PERMIT (Spey mason-for local use only) (Specify change-for local use only) ❑ S. TANK REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY IDN 1 <br /> LOCATION WITHIN SITE(Oplionaq 431 <br /> 1.TANK DESCRIPTION <br /> TANK to N TANK MANUFACTURER COMPARTMENTALIZED TANK P Yes ❑ No <br /> If'Yei,complete one page for each compartment. <br /> Joor <br /> DATE INSTALLED(YEAR/MO) TANK CAPACITY IN GALLONS NUMBER OF COMPARTMENTS <br /> q-1-0o i 100 2 <br /> ADDITIONAL DESCRIPTION(Forlocal use only) <br /> II.TANK CONTENTS <br /> TANK USE 432 PETROLEUM TYPE <br /> UU/1'1. MOTOR VEHICLE FUEL la. REGULAR UNLEADED ❑ 2. LEADED ❑ 5. JET FUEL <br /> (It marked,complete Petroleum Type) ❑1b PREMIUM UNLEADED ❑ 3. DIESEL ❑ 6. AVIATION FUEL <br /> ❑ 2. NON-FUEL PETROLEUM ❑1c. MIDGRADE UNLEADED ❑ 4. GASOHOL ❑99. OTHER <br /> ❑ 3. CHEMICAL PRODUCTCAS N(from Hazardous Materials Inventory page) <br /> COMMON NAME(from Hazardous M rials Inventory pag) <br /> ❑ 4. HAZARDOUS WASTE(Includes <br /> Used Oil) <br /> El 95 UNKNOWN I <br /> II ANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1. SINGLE WALL 3. LE WALL WITH ❑ 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM <br /> TERIOR MEMBRANE LINER ❑95. UNKNOWN <br /> (Check one item only) . DOUBLE WALL <br /> 4. SINGLE WALL IN A VAULT ❑yq OTHER <br /> TANK MATERIAL•primary tank 1 BARE STEEL ❑ 3. FIBERGLASS/PLASTIC ❑ 5. CONCRETE ❑95. UNKNOWN <br /> (Check one item only) ❑ 2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑ 8. FRP COMPATIBLE W1100%METHANOL ❑99. OTHER <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL-secondary tank ❑ 1 BARE STEEL ❑ 3. FIBERGLASS/PLASTIC �❑/'8. FRP COMPATIBLE WI100%METHANOL ❑95. UNKNOWN <br /> (Check one item only) ❑ 2. STAINLESS STEEL ❑ 4. STEEL CLAD WIFIBERGLASS 1Q 9. FRP NON-CORRODIBLE JACKET ❑99. OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> ❑ <br /> S. CONCRETE <br /> TANK INTERIOR LINING DATE INSTALLED <br /> OR COATING ❑ 1. RUBBER LINED ❑ 3. EPDXY LINING ❑ 5. GLASS LINING ❑95. UNKNOWN433 <br /> ❑ 2. ALKYD LINING ❑ 4. PHENOLIC LINING V8. UNLINED ❑99. OTHER (For local use only) <br /> (Check one item on ) DATE INSTALLED <br /> OTHER CORROSION ❑ 1. MANUFACTURED CATHODIC 3, FIBERGLASS REINFORCED PLASTIC ❑95. UNKNOWN 434 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> ❑ 4. IMPRESSED CURRENT ❑99. OTHER (For local use only) <br /> (Check one item only) ❑ 2. SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAR INSTALLED TYPE(For local use onty) OVERFILL PROTECTION EQUIPMENT.YEAR INSTALLED <br /> (Check all that apply) �I( 1. SPILL CONTAINMENT ❑ 1. ALARM 7,3, FILL TUBE SHUT OFF VALVE <br /> �2. DROP TUBE ❑ 2. BALL FLOAT ❑ 4. EXEMPT <br /> X3. STRIKER PLATE560.J <br /> N,TANK LEAK DETECTION <br /> IF SINGLE WALL TANK Check all that a ): IF DOUBLE WALL TANK OR TANK WITH BLADDER(Check one item only): <br /> ❑ 1, VISUAL(EXPOSED PORTION ONLY) ❑ 5. MANUAL TANK GAUGING(MTG) 1. VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 2. AUTOMATIC TANK GAUGING(ATG) ❑ S. VADOSE ZONE CONTINUOUS INTERSTITIAL MONITORING <br /> ❑ 3. CONTINUOUSATG - ❑ 7. GROUNDWATER ❑ 3. MANUAL MONITORING <br /> ❑ 4. STATISTICAL INVENTORY RECONCILIATION(SIR) ❑ 8. TANK TESTING <br /> BIENNIAL TANK TESTING - 099, OTHER <br /> V.TANK CLOSURE INFORMATION)PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) ESTIMATED QUANTITY OF SUBSTANCE REMAINING 435 1 TANK FILLED WITH INERT MATERIAL? <br /> gallons ❑Yes ❑No <br /> o0 -3 <br /> T�oS/5.5.3CP <br /> CUPAFORM(4/99) • . Formerly SWRCB Form B <br /> c, � t1310 <br />
The URL can be used to link to this page
Your browser does not support the video tag.