My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3304
>
2300 - Underground Storage Tank Program
>
PR0516354
>
COMPLIANCE INFO_2008-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2021 2:01:45 PM
Creation date
6/3/2020 10:00:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2018
RECORD_ID
PR0516354
PE
2361
FACILITY_ID
FA0012437
FACILITY_NAME
CHEVRON 352324
STREET_NUMBER
3304
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
07120013
CURRENT_STATUS
01
SITE_LOCATION
3304 W HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0516354_3304 W HAMMER_2008-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
455
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
low 'qW <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 �� <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd 'g q-I 61 <br /> UndergrounjdSt ' �` <br /> , � e � ora ean�C Programinspect�on� ep <br /> Wn, ,. r. ..�. ... <br /> T , ,. ., > <br /> , <br /> ___7 <br /> Facility Name: Facility Address: Date: <br /> HAMMER LANE OIL INC 3304 W HAMMER LN STOCKTON June 13 2016 <br /> e <br /> x$�� '" ., 'rs`ab?4� rs.'°��,,as. � v:-: � <br /> USr,. Sysm ®bservat'ons .. bra E � <br /> .ds�n•,&.e�a..�a, � <br /> 326 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 327 HSC 25298(b) Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 328 HSC 25298(c) Failed to comply with permanent closure requirements ❑V ❑R ❑COS <br /> 329 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system ❑V ❑R ❑COS <br /> n- ressur�zed Pip ng <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> R- 15111 <br /> Otero Violat�ons � IN <br /> rE k ,4� � �1x .h `..a.. . ..,. � .. <br /> 2010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V ❑R ❑COS <br /> ARRI( QFC VI�QL�AT �� ��" � <br /> �C S �I G SSII,or MINOR once to on <br /> Item# Remarks <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted. <br /> Financial responsibility documents have not been submitted to the EHD. Current financial responsibility documents <br /> are required to be submitted annually. Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov/, and upload the required documents. <br /> This is a repeat violation, Class II. <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> Maintenance and monitoring records for the last three years were not found on site. The 2014 and 2013 monitoring <br /> system certification test results were not found onsite. These records shall be maintained on site for at least three <br /> years. Monitoring records include: (1) date and time of all monitoring or sampling; (2)monitoring equipment calibration <br /> and maintenance records; (3) results of any visual observations; (4) results of sample analysis performed a lab or in <br /> the field; (5) logs of all readings of gauges or other monitoring equipment, ground water elevations, or other test <br /> results; (6) results of inventory readings and reconciliations. Immediately locate and maintain all maintenance and <br /> monitoring records for the last three years on site and submit copies to the EHD. <br /> This is a minor violation. <br /> Page 3 of 4 <br />