Laserfiche WebLink
Locking <br /> Well plug with Steel stovepipe <br /> O-ring seal monument with <br /> locking cover <br /> IM <br /> FIN <br /> 4-inch Schedule 80 <br /> PVC blank casing <br /> Portland grout tremie application <br /> Bentonite seal <br /> Filter sand <br /> 4-inch Schedule 80 PVC =_ <br /> casing,0.020-inch slot <br /> 4-inch PVC flush thread = <br /> bottom cap = <br /> Estimated Total Depth= 300 feet bgs <br /> Notes: Typical Monitoring Well Construction Diagram <br /> bgs—below ground surface <br /> Actual depths will be determined based June GSH Lathrop Facility Geosyntec <br /> on field conditions during installation. :2018 Joaquin County,California consultants <br />