My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0010635
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TENTH
>
60
>
3500 - Local Oversight Program
>
PR0545724
>
ARCHIVED REPORTS_XR0010635
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/3/2020 1:16:51 PM
Creation date
6/3/2020 1:08:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0010635
RECORD_ID
PR0545724
PE
3528
FACILITY_ID
FA0005934
FACILITY_NAME
M & M AUTOMOTIVE
STREET_NUMBER
60
Direction
E
STREET_NAME
TENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23517204
CURRENT_STATUS
02
SITE_LOCATION
60 E TENTH ST
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Wright Environmental Services, Inc. <br /> Monitoring Well Construction <br /> 1. The proper permits will be obtained from the appropriate agency or water <br /> district, scheduling a Well Inspector as required to be present to witness the <br /> installation of the annular seal Soil borings will be drilled with a continuous-flight <br /> hollow-stem auger of nominal 8 inches outside diameter (to leave 2-inch annular <br /> space for well construction). All augers will be thoroughly steam-cleaned pnor to <br /> arriving at the site. The augers will be steamed cleaned between borings at a location <br /> well away from the proposed borings or adequate clean auger will be available to <br /> complete all of the wells without reusing auger sections. <br /> 2. The borings will be advanced to the uppermost water bearing zone (or a depth <br /> of 45 feet if a saturated zone is not encountered and in absence of other exploration <br /> depth specifications). If a saturated zone is encountered, the boring will advance no <br /> further than 15 feet below first encountered groundwater or 5 feet into the <br /> underlying clay aquitard. If entered, a seal will be placed in the overdnlled portion <br /> of the aquitard. <br /> 3. During the drilling operations, 55-gallon drums will be on site to contain <br /> potentially contaminated soils, drilling muck and rinse water to minimize surface <br /> contamination. <br /> 4. Where borings are completed as groundwater monitoring wells, 2-inch ID <br /> schedule 40 PVC blank pipe will be used Well screen selection will be 2 inch ID <br /> Schedule 40 PVC pipe with 0 020 inch machine slot (in absence of other <br /> specifications) Sections will be threaded and screwed flush together, glues will not <br /> be used Screens will extend 3-5 feet above first encountered groundwater The <br /> annulus of the perforated section will be packed with clean #3 or #4 Monterey Sand, <br /> Lonestar 2/12 Sand or equivalent, to a level about 2-feet above the screen interval <br /> (field experience has shown this monitoring well design has worked well in <br /> stratified alluvial and fine grained environments, if special well designs supersede <br /> this design, a specification will be attached). <br /> Final well design will be adjusted in the field to site specific subsurface conditions <br /> observed in the borehole, and well screens or slots will be placed so as not to <br /> interconnect two possible aquifers or uncontaminated vadose zone strata Screens <br /> will extend a nominal length (up to 5 feet) above first encountered unconfined <br /> groundwater for floating product detection where needed A 1-2 foot thick bentonite <br /> seal will be placed on top of the sandpack A cement grout annular seal which <br /> extends to the surface will be placed by tremie line from the bottom to top of the <br /> remaining annular space above the bentonite Sealing can be modified as regulatory <br /> input requires. <br /> 6. The top of the well casing will be locked to prevent contamination and <br /> tampering An above-grade or at-grade well completion will depend upon well <br /> location At-grade completions require traffic rated boxed set in concrete or Cement <br /> grout just above grade. Above-grade completion will require a 6-inch diameter <br /> locking, steel protective "stovepipe" casing and a Christy, or equivalent, traffic box <br /> and concrete pad and surface poles or barriers to mark the location <br /> WES Sampling Protocols last rev 2/96 Page 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.