Laserfiche WebLink
: SA NUJ FAQ U I N Environmental Health Department <br /> ._ <br /> COUNTY— <br /> Time <br /> OUNTY <br /> Tl <br /> E"r : <br /> ^'•ti7F Opt�� Greotness grows here. 9am <br /> Timee OOutut: 9::330 0 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: VINTAGE SQUARE APTS Date: 06/03/2020 <br /> Address: 1176 ROSEMARIE LN, STOCKTON 95207 <br /> Owner/Operator: VINTAGE PROPERTY LP Telephone: (209)478-0310 <br /> Program Element: 3612-PUBLIC POOL/SPA-ADDITIONAL <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #2 Pool Enclosure <br /> OBSERVATIONS:West/South metal bar is vent. It shall be straighten by 1 week(repeat violation). <br /> Loose bar at north end. Repair immediately all loose bars to prevent an accidental drowning. <br /> CALCODE DESCRIPTION:Pool area shall be enclosed by one or more of the following:a fence,portion of a building, wall, or other <br /> approved durable enclosure.Pool enclosure shall be constructed over a hard permanent material equivalent to concrete and shall be <br /> installed no more than 2 inches above the finished grade. Holes,gaps,or openings in the enclosure shall not allow the passage of a <br /> 4-inch diameter sphere.Doors, openable windows,or gates of living quarters shall not be permitted as part of the pool enclosure. (CBC <br /> 3119B) Pool operator shall keep the pool enclosure well maintained. (CCR 65535) Pool enclosure shall have a minimum effective <br /> perpendicular height of 5 feet and shall be constructed so that it cannot be climbed by small children.Horizontal members shall be spaced <br /> at least 48 inches apart. No planters or other climbable structures shall be permitted within 5 feet of the pool enclosure or within a 5-foot <br /> arc. Chain link openings shall not be larger than 1314 inches when measured horizontally. Pool enclosures with a height of 4 or more feet <br /> are allowed if the enclosure was constructed prior to July 1994. (CBC 3119B) <br /> #7 Pool Deck <br /> OBSERVATIONS:Excess old vegetation on deck. Clean deck on a routine basis to prevent vegetation from going into pool <br /> water. <br /> CALCODE DESCRIPTION:An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br /> top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br /> diving board,ADA device, or slide. (CBC 3114B)Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #46 Other <br /> OBSERVATIONS:Old trash/clutter in pump room. Remove old clutter and trash by 1 week. <br /> CALCODE DESCRIPTION:Other violation not listed. <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 35 gpm Chlorine: 5.2 ppm Temp: ° F <br /> Cyanuric acid: 0 ppm pH: 7.6 Combined chlorine: 0.2 ppm <br /> NOTES <br /> FA0001219 PR0360237 SCO01 06/03/2020 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />