Laserfiche WebLink
■ ■ Formerly Iris Environmental <br /> Abaxis Solution: <br /> Waste analysis found on the Abaxis website for the HM5 Hematology System (August 24, 2015) Budapest, Hungary(attached) <br /> Abaxis Waste has the following components (according to Diatron MI Plc.—Waste Certification for the HM5 HEMATOLOGY SYSTEM) <br /> Phys Acute Oral Toxicity Acute Dermal Acute Inhalation <br /> Components prop Concentration Density (LDso) Toxicity(LD50) Toxicity(LC50) Other Notes <br /> Isopropanol Flammabl73 mg/L @ 100%IPA Not classified as a human <br /> (100%unless e 105—120 mg/L 785 kg/m3 5,045 mg/kg 12,870 mg/kg >10,000 mg/L @20% carcinogen;No significant risk <br /> noted) IPA level for California. <br /> Phosphate as P None 890—940 mg/L N/A N/A N/A No info None <br /> 1190-1270 >10,000 mg/kg <br /> Chloride None mg/L N/A 3,000 mg/kg(NaCl) (NaCl) No info None <br /> TOC N/A 240—250 mg/L N/A N/A N/A N/A <br /> Note:All component information provided be Safety Data Sheets identified online. <br /> Has the waste been delisted or excluded? No,it is a waste under federal and the CA definition <br /> Is the waste a listed RCRA hazardous waste(F,K, P,U)?(Title 22 CCR Chapter 11 Article No <br /> 4) <br /> Does the waste have a hazardous component(X,C,I,R)?(Title 22 CCR Chapter 11 Yes,but is at a concentration that it is considered an aqueous solution <br /> Appendix X) <br /> Does the waste exhibit any Article 3 criteria?(Title 22 CCR Chapter 11 Article 3) No <br /> Is the waste ignitable? Aqueous solution with<24%alcohol is not characteristically ignitable(22 CCR <br /> 66261.21(a)(1)) <br /> Is the waste corrosive? No,pH is 7.0 <br /> Is the waste reactive? No,the waste is stable under normal conditions <br /> Is the waste a toxicity characteristic waste? No,no components are included in the list of contaminants <br /> Is the waste an acute hazardous waste? No <br /> Is the waste a toxic waste?(Oral LD50<2500 mg/kg;Dermal LD5o<4300 mg/kg;Inhalation No,all components of the waste have doses greater than the hazardous <br /> LC50<10,000 ppm;Aquatic Toxicity LC5o<500 mg/L) characteristic with the exception inhalation. Review of an SDS for a 20%IPA <br /> solution indicates an inhalation dose of>10,000 ppm.The weight percent of IPA <br /> in the Abaxis waste is<1%. <br /> Is the waste considered a non-RCRA hazardous waste as listed on the M list? No,the waste does not contain mercury. <br /> Is the waste an acutely or extremely hazardous waste that would cause death,disabling No <br /> personal injury,or serious illness. <br /> Energy I Environmental Risk I Infrastructure I Ocean Science <br />