My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0010740
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
9110
>
3500 - Local Oversight Program
>
PR0545727
>
ARCHIVED REPORTS_XR0010740
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2020 11:46:31 AM
Creation date
6/4/2020 11:32:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0010740
RECORD_ID
PR0545727
PE
3528
FACILITY_ID
FA0005693
FACILITY_NAME
7-ELEVEN INC. STORE #20680
STREET_NUMBER
9110
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Stockton
Zip
95209
CURRENT_STATUS
02
SITE_LOCATION
9110 Thornton Rd
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GROUNDWATER TECHNOLOGY, INC. <br /> STANDARD OPERATING PROCEDURE <br /> CONCERNING OPERATION/CALIBRATION OF <br /> PHOTOIONIZATION ANALYZER <br /> SOP 19 <br /> 1 The Thermo Environmental Instruments Inc Model 580B OVM Photolonization Analyzer shall be <br /> used, using photoionization,to measure the concentration of trace gases over a range of less than <br /> 1 ppm to 2,000 ppm The specific Instrument used for investigations related to hydrocarbon <br /> contamination should be calibrated for direct readings In parts per million (ppm) volume/volume <br /> of isobutylene Specifics of the detection principle/theory and functions of various components can <br /> be found in the manufactures Instruction manual <br /> 2 To assure optimum performance,the photoionization analyzer should be calibrated with a standard <br /> gas mixture of known concentration from a pressurized container A daily procedure for calibration <br /> Involves bringing the probe and readout close to the calibration gas, cracking the valve on the tank <br /> and checking the Instrument reading This provides a useful spot check for the Instrument <br /> 3 A procedure conducted weekly for more accurate calibration of the instrument from a pressurized <br /> container is to connect one side of a T to the pressurized container of calibration gas,another side <br /> of the T to a rotameter and the third side of the T directly to the W extension to the <br /> photolonization probe(see Figure 2) Crack the valve of the pressurized container until a slight flow <br /> Is Indicated on the rotameter The Instrument draws In the volume of sample required for detection, <br /> and the flow in the rotameter Indicates an excess of sample Now adjust the span pot so that the <br /> Instrument reads the exact value of the calibration gas (If the instrument span setting Is changed, <br /> . the Instrument should be turned back to the standby position and the electronic zero should be <br /> readjusted, If necessary) <br /> GROUNDWATER <br /> [ __I TECHNOLOGY, INC <br />
The URL can be used to link to this page
Your browser does not support the video tag.