Laserfiche WebLink
Hazardous Determination <br /> Case • le Result: Home Armor1 <br /> Is it Listed Hazardous Waste? <br /> Is it a Solid Waste? No. Since this material was unused product, the F and K lists do not apply& only P <br /> 40 CFR Part 261.2 and U lists need to be considered. According to the SDS, composition information, <br /> there were no P or U listed constituents in this product. <br /> Is it excluded from Solid Waste Does it exhibit a Characteristic? <br /> regulation? D001 Ignitable: Does this material have a flashpoint<140' F? <br /> 40 CFR 261.2 and 261.4 Potentially. Since the MSDS does not contain any information on <br /> ignitability, it is recommended to consult a second source of information. <br /> Is it excluded from Hazardous D002 Corrosive: Does this material have a pH <_2.0 or >_12.5? <br /> Waste regulation? Potentially. The pH of this material is 12.0 - 13.0. Since this material is <br /> 40 CFR 261.3 and corrosive at 12.5, and non-corrosive at 12.0 - 12.4, unless the site has <br /> analytical data to prove a pH < 12.5, this material should be conservatively <br /> classified as D002 corrosive. <br /> Is it Listed Hazardous Waste? <br /> 40 CFR 261.30 and 261.35 D003 Reactive: Is this material unstable under normal conditions? <br /> No. This material appears stable under Standard Temperature and <br /> ' Pressure. <br /> Does it exhibit a Hazardous Waste <br /> Characteristic? D004- D043 Toxic: Does this material exhibit the characteristic of toxicity? <br /> 40 CFR 261.20 and 261.24 No. This material does not contain any D-listed/Toxic constituents. <br /> 9/23/2019 Amazon Confidential 55 EHS <br />