Laserfiche WebLink
SA NUJ OAHU I N Environmental Health Department <br /> L■ COUNT Y-- <br /> �c/ `p' Greo[ness grows hey,. Timeln: 9-15am <br /> Time Out: 10:15 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: STONETREE CONDOMINIUMS Date: 06/04/2020 <br /> Address: 1819 S CHEROKEE LN, LODI 95240 <br /> Owner/Operator: STONETREE CONDOMINIUMS OWNERS Telephone: <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #3 Safety Signs <br /> OBSERVATIONS:The following signs were missing. Provided within one week: <br /> • Keep closed signed is missing.A sign shall be posted on the exterior side of gates and doors leading into the pool <br /> enclosure area stating, "KEEP GATE CLOSED"or"KEEP DOOR CLOSED". <br /> • Diarrhea Sign:The pool operator shall post at the entrance area of a public pool, a sign in letters at least 1 inch (25 mm) <br /> high,that clearly states that persons with diarrhea and persons who have had diarrhea within the prior 14 days shall not <br /> enter the pool water. <br /> CALCODE DESCRIPTION:Pool operator shall keep safety signs well maintained. (CCR 65535)Safety signs shall have clearly legible <br /> letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall,pole,gate, or similar <br /> permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 31208) <br /> #7 Pool Deck <br /> OBSERVATIONS:There are gaps between pool deck and concrete floor. Seal these gaps within one month. <br /> CALCODE DESCRIPTION:An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br /> top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br /> diving board,ADA device, or slide. (CBC 31148)Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #18 Pool Shell and Tile <br /> OBSERVATIONS:There are damages/chips/holes observed at the bottom of pools. Repair or patch these damages within <br /> one month. <br /> CALCODE DESCRIPTION:Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br /> and scrubbing.A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 31088) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 60 gpm Chlorine: 7.8 ppm Temp: ° F <br /> Cyanuric acid: >100 ppm pH: 7.8 Combined chlorine: 0 ppm <br /> NOTES <br /> FA0000601 PR0360140 SCO01 06/04/2020 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />