Laserfiche WebLink
L <br /> 1 i <br /> it <br /> 15 June 2004 <br /> AGE-NC Project No 96-0254 <br /> Page 3 of 4 <br /> The ground water flow direction at the time of the Fourth Quarter 2003 sampling event was inferred <br /> to be toward the north-northeast at an average hydraulic gradient of 0 005 foot/foot (Figure 3) <br /> During the First Quarter 2004 sampling event, ground water flow was inferred to be towards the <br /> north-northwest at an average gradient of 0 004 ft/ft(Figure 4) Data from the deeper-screened well <br /> MW-2A was not used to determine the ground water gradient for either monitoring event <br /> 3 2 LABORATORY RESULTS OF GROUND WATER SAMPLES <br /> The following summary of laboratory results includes the results from the Fourth Quarter 2003 and <br /> First Quarter 2004 monitoring events <br /> 3 2 1 Fourth Quarter 2003 Laboratory Results <br /> TPH-g,BTEX compounds and fuel additives were detected only in ground water samples collected <br /> from wells MW-4 and MW-7 TPH-g was detected at concentrations of 360 micrograms per liter <br /> . (µg11) from MW-4 and 2,800 µg/1 from MW-7 BTEX compounds were detected at maximum <br /> concentrations of 1,600 µg/1 benzene, 170 µg/1 toluene,63 µg/1 ethylbenzene and 220 µg/l xylenes, <br /> in MW-7 The fuel additive TAME was detected in the sample from MW-7 at 50µg11, and 1,2-DCA <br /> was detected in the samples from MW-4 and MW-7 at 13 µg/1 and 50 µg/1, respectively <br /> 3 2 2 First Quarter 2004 Laboratory Results <br /> TPH-g was detected in samples from MW-1B and MW-4 at concentrations of 150µg/l and 340µg/1, <br /> respectively In addition,TPH-d was detected in MW-4 at a concentration of 64 µg11,the laboratory <br /> reported that the TPH-d had significant gasoline range compounds and significant diesel range <br /> compounds with no recognizable pattern BTEX compounds were detected in samples from MW-113 <br /> and MW-4 at maximum concentrations of 100µg/1 benzene and 2 8 µg/l ethylbenzene in the MW-4 <br /> sample and 2 1 µg/l toluene and 11 µg/1 xylenes in the sample from MW-1B <br /> The fuel additive MTBE was detected in samples from MW-1B, MW-213 and MW-4 at <br /> concentrations of 0 90 µg/l, 14 µg/1 and 3 5 µg/l, respectively <br /> No other target analytes were detected in the ground water samples The analytical results are <br /> summarized in Tables 2 and 3 Copies of the laboratory reports(CTEL Project No CT214-0312094 <br /> and MAI Work Order 0403052), QA/QC reports and chain-of-custody forms are in Appendix B <br /> Advanced GeoEnviro n mental Inc <br />