My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0009267
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TOSTE
>
2450
>
3500 - Local Oversight Program
>
PR0545734
>
ARCHIVED REPORTS_XR0009267
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2020 2:06:10 PM
Creation date
6/5/2020 1:35:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0009267
RECORD_ID
PR0545734
PE
3528
FACILITY_ID
FA0010191
FACILITY_NAME
TRACY-PONTIAC-CADILLAC-GMC TRUCK
STREET_NUMBER
2450
STREET_NAME
TOSTE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
238020-06
CURRENT_STATUS
02
SITE_LOCATION
2450 TOSTE RD
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Quarters ort - March 1999 <br /> • Y Report <br /> Former Curtiss Pontiac Buick <br /> 2450 Toste Road, Tracy, California <br /> 1.0. INTRODUCTION <br /> At the request of Mr Joe Taste, Advanced GeoEnvironmental, Inc (AGE) has prepared this <br /> Quarterly Report for 2450 Toste Road, Tracy, California(the site) The scope of work included the <br /> sampling of five ground water monitoring wells The site setting is illustrated in Figure 1 A plan <br /> view of the site is illustrated in Figure 2. <br /> A summary of previous investigation at the site is included in the Preliminary Investigation and <br /> Evaluation Report(PIER),prepared by AGE, dated 15 August 1997 and Quarterly Report, prepared <br /> by AGE, dated 18 September 1997 Ground water monitoring data collected from monitoring well <br /> MW-3,which is part of the underground storage tank(UST)release investigation at 2420 Grant Line <br /> I Road, is included in this investigation to delineate the down gradient extent of the dissolved <br /> hydrocarbon plume and to determine ground water flow direction and gradient <br /> This report is prepared in accordance with Central Valley Regional Water Quality Control Board and <br /> San Joaquin County Public Health Services - Environmental Health Division (PHS-EHD) <br /> guidelines <br /> 2.0. PROCEDURES <br /> The ground water monitoring activities were conducted in accordance with Central Valley Regional <br /> I Water Quality Control Board and San Joaquin County Public Health Services - Environmental <br /> Health Division (PHS-EHD) guidelines <br /> 21 GROUND WATER DEPTH MEASUREMENT AND PURGING <br /> On 25 March 1999, a Solinst water level meter was used to measure the depth to ground water in <br /> each well relative to the tops of the well casings After ground water depth measurements were <br /> collected,monitoring wells MW-IA and MW-2A were purged using a two-stage submersible pump, <br /> Iwhile wells MW-1 B,MW-2B,MW-3,MW-5 and MW-6 were purged with pre-cleaned PVC bailers <br /> Three gallons of water (a minimum of 3 well volumes per well) were evacuated from MW-6, four <br /> gallons of water were removed from wells MW-IB, MW-2B, MW-3 and MW-5, and ten gallons of <br /> water were purged from MW-1A and MW-2A <br /> Temperature,pH and conductivity were measured at 1-gallon intervals in wells MW-IB, MW-2B, <br /> MW-3, MW-5 and MW-6, and at 2-gallon intervals in wells MW-IA and MW-2A The field data <br /> were measured with an ICM model 52200 water analyzer Logs of the field data are included in <br /> IAppendix A Purged water was stored on-site in labeled 55-gallon drums <br /> Advanced GeoEnvironmental Inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.