Laserfiche WebLink
! y <br />! Quarterly Report - December 1998 <br /> Former Curtiss Pontiac Buick <br />! 2450 Toste Road, Tracy, California <br />! 1.0. INTRODUCTION <br /> At the request of Mr Joe Toste, Advanced GeoEnvironmental, Inc (AGE) has prepared this <br />! Quarterly Report for 2450 Toste Road, Tracy, California (the site) The scope of work Included the <br /> sampling of five ground water monitoring wells The site setting Is Illustrated in Figure 1 A plan <br />! view of the site is illustrated in Figure 2 <br /> A summary of previous investigation at the site is included in the Prehminary Investigation and <br />! Evaluation Report(PIER),prepared by AGE, dated 15 August 1997 and Quarterly Report,prepared <br /> by AGE, dated 18 September 1997 Ground water monitoring data collected from monitoring well <br /> MW-3,parts of the underground storage tank(UST)release Investigation at 2420 Grant Line Road <br />! are Included in this Investigation to delineate the down gradient extent of the dissolved hydrocarbon <br /> plume and to determine ground water flow direction and gradient <br />' This report is prepared in accordance with Central Valley Regional Water Quality Control Board and <br /> San Joaquin County Public Health Services - Environmental Health Division (PHS-EHD) <br />� . guidelines for the subsurface Investigation of UST sites <br /> 2.0. PROCEDURES <br /> The ground water monitoring activities were conducted in accordance with Central Valley Regional <br /> Water Quality Control Board and San Joaquin County Public Health Services - Environmental <br /> Health Division(PHS-EHD) guidelines for the subsurface Investigation of UST sites <br /> 2 1 GROUND WATER DEPTH MEASUREMENT AND PURGING <br /> On 17 December 1998,a Solinst water level meter was used to measure the depth to ground water <br /> in each well relative to the tops of the well casings After ground water depth measurements were <br /> collected, each monitoring well was purged using a two-stage submersible pump Three gallons of <br /> water(a minimum of 3 well volumes per well)were evacuated from MW-3, MW-5 and MW-6, four <br /> gallons of water were removed from wells MW-1B, MW-2B and ten gallons of water were purged <br />' from MW-lA and MW-2A <br /> Temperature,pH and conductivity were measured at I-gallon intervals In wells MW-1 B, MW-2B, <br /> MW-3, MW-5 and MW-6, and at 2-gallon intervals in wells MW-IA and MW-2A The field data <br /> • were measured with an ICM model 52200 water analyzer Logs of the field data are included in <br /> Appendix A Purged water was stored on-site in labeled 55-gallon drums <br /> Advanced GeoEnvironmental Inc <br />