My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE HISTORY
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3425
>
3500 - Local Oversight Program
>
PR0545737
>
SITE HISTORY
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2020 2:30:49 PM
Creation date
6/5/2020 2:21:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE HISTORY
RECORD_ID
PR0545737
PE
3528
FACILITY_ID
FA0003627
FACILITY_NAME
ARCO 02093
STREET_NUMBER
3425
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418020
CURRENT_STATUS
02
SITE_LOCATION
3425 TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
208
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BROWN AND CALDWE.LL ANALYTICAL LABORATORIES SEP <br /> BATCH QC REPORT ;°3viRONMENTAL HFA"�+ <br /> Defuutions and Terms PERMIT/SERVICES <br /> Accuracy: The ability of a procedure to determine the "true'concentration of an <br /> analyte. <br /> Batch: A group of samples analyzed sequentially using the same calibration curve, <br /> reagents, and instrument. <br /> i <br /> Laboratory Control Laboratory reagent water spiked with known compounds and subjected <br /> Standard (LCS): to the same procedures as the samples. The LCS thus indicates the accuracy <br /> of the analytical method and,because it is prepared from a different source <br /> than the standard used to calibrate the instrument, it also serves to double- <br /> check the calibration. <br /> LC.Result: Laboratory result of an LCS analysis. <br /> LT Result: Expected result, or true value,of the LCS analysis. <br /> Matrix QC: Quality control tests performed on actual client samples. For most inorganic <br /> analyses,the laboratory uses a pair of duplicate samples and a spiked <br /> sample. For most organic analyses,the laboratory uses a pair of spiked <br /> samples (duplicate spikes). <br /> Percent Recovery: The percentage of analyte recovered.. <br /> For LCS, the percent recovery calculatioa is <br /> LC + LTx 100. <br /> For spike recoveries, the percent recovery calculatlion is <br /> (S Bax`- Sample Concentration} x 100 <br /> Spike Amount <br /> Precision: The reproducibility of a procedure demonstrated by the agreement between <br /> analyses performed on either duplicates of the same sample or a pair of, <br /> duplicate spikes. <br /> R 1, R2 Result: Result of the analysis of replicate aliquots of a sample, with R 1 indicating <br /> the first analysis of the sample and R2 its corresponding duplicate; used to . <br /> det:erraine precision. <br /> Relative Percent Calculated using one of the following: <br /> Difference(RPD): <br /> (R I - R2) x 100 (Sl - S2) x 100 <br /> (RI + R2) _ 2 (SI + S2) = 2 <br /> S Bar Result: The average of spike analysis results. <br /> S1, S2 Result: Result of the analysis of replicate spiked aliquots,with S I indicating one <br /> spike of the sample and S2 the second spike;used to determine precision <br /> and accuracy_ <br /> True value: The theoretical, or expected, result-of a spike sample analysis_ <br />
The URL can be used to link to this page
Your browser does not support the video tag.