Laserfiche WebLink
Page 12 of 23 Standard Operating Procedures <br /> Health and Safety Plans <br /> 2 Cntena for selection <br /> PID instrument (such as OVM 580B) readings in the breathing zone are less than 100 <br /> ppm Work functions preclude splashes, immersion, or potential for unexpected <br /> inhalation of any chemicals <br /> NOTE Modifications of Level D will be used to increase the level of skin protection during <br /> activities which increase the degree of contact with chemical hazards. These modifications <br /> include the use of chemical resistant coveralls (e.g , tyveks) and chemical resistant gloves <br /> Level C Protection <br /> 1 Personal protective equipment <br /> - Full-face, air-purifying, cartridge-equipped respirator (MSHAINIOSH approved) <br /> - Chemical-resistant clothing (coverall; hooded, two- piece chemical splash suit; <br /> chemical-resistant hood and apron, disposable chemical-resistant coveralls) <br /> - Cotton or synthetic coveralls* <br /> - Gloves (outer), chemical-resistant - nitriles <br /> - Gloves (inner), chemical-resistant - latex <br /> - Boots (outer), chemical-resistant, steel toe and shank <br /> - Boots (outer), chemical-resistant (disposable*) <br /> - Hard hat (face shield*) <br /> - Escape mask* <br /> - 2-Way radio communications (intrinsically safe)* <br /> *Optional <br /> 2 Criteria for selection <br /> - Continuous total vapor readings register greater than 100 ppm on PID instruments <br /> (such as the OVM 580B) <br /> ROUX ASSOCIATES HASP 4193 3425 Tracy Boulevard <br /> Tracy,California <br />