Laserfiche WebLink
_it <br /> f <br /> STANDARD OPERATING PROCEDURE - <br /> GROUNDWATER SAMPLING <br /> Gettler-Ryan Inc field personnel adhere to'the following'procedures for the collection and handling of <br /> groundwater samples prior to analysis by the analytical-laboratory—Prior to sample collection,-the type of <br /> analysis to be performed is determined Loss prevention of volatile compounds is controlled and sample <br /> preservation for subsequent analysis is maintaned' <br /> Prior to sampling, the presence or absence of free-phase hydrocarbons is determined using an interface <br /> probe Product thickness, if present, is measured to the nearest 0 01 foot and is noted in the field notes <br />-� --� in addition,all depth to water-level measurements are collected with a static water level,indicator and are «� <br /> also recorded in the field notes, prior to purging and sampling any wells <br /> After water levels are collected and prior to sampling, if purging`is to occur, each well is purged a <br /> minimum of three well casing volumes of water using pre-cleaned pumps (stack, suction, Grundfos), or <br /> disposable bailers Temperature,pH and electrical conductivity are measured a minimum of three times <br /> during the purging Purging continues until these parameters stabilize <br /> Groundwater samples are collected using disposable bailers The water samples are transferred from the <br /> bailer into appropriate containers Pre-preserved containers,supplied by analytical laboratories,are used <br /> when possible When pre-preserved containers are not available,the laboratory is instructed to preserve <br /> the sample as appropriate Duplicate samples are collected for the laboratory to use in maintaining <br /> quality assurance/quality control standards The samples a;e labeled to include the job number, sample <br /> identification,collection date and time,analysis,preservation(if any),and the sample collector's initials <br /> The water samples are placed m a cooler;maintained at 40C�for transport-to the laboratory Once <br /> collected in the field, all samples are maintained under chain of custody until delivered to the laboratory <br /> The chain of custody document includes the job number,type of preservation, if any,analysis requested, <br /> sample identification, date and time collected, and the sample collector's name The chain of custody is <br /> signed-and-dated-(jncludmg-time-of_transfer)-by_each_person who_receives_or surrenders_the samples, <br /> beginning with the field personnel and ending with the laboratory personnel <br /> A laboratory supplied trip blank accompanies each 'sampling set For sampling sets greater than 20 <br /> samples, 5%trip blanks are included The trip blank is analyzed for some or all of the same compounds <br /> as the groundwater samples <br /> As requested by ChevronTexaco Company,the purge water and decontamination water generated during <br /> sampling activities is transported by IWM to McKittrick Waste Management located in McKittrick, <br /> California <br /> N\Cahfonnakfonnskhevran-SOP 03-15 04 <br />