Laserfiche WebLink
� ZZZ <br /> z Z Z Z <br /> w 60 6 D a I <br /> N a SERVICES, INCORPORATED <br /> MPDS-UN6348-04 <br /> October 7, 1994 <br /> Unocal Corporation <br /> 2000 Crow Canyon Place, Suite 400 <br /> P o Box 5155 <br /> San Ramon, California 94583 <br /> Attention Mr Edward C Ralston <br /> RE Quarterly Data Report <br /> Former Unocal Service Station #6348 <br /> 3788 Tracy Boulevard <br /> Tracy, California <br /> Dear Mr Ralston <br /> This data report presents the results of the most recent quarter of <br /> monitoring and sampling of the monitoring wells at the referenced site <br /> by MPDS Services, Inc <br /> RECENT FIELD ACTIVITIES <br /> The monitoring wells that were monitored and sampled during this <br /> quarter are indicated in Table 1 Prior to sampling, the wells were <br /> checked for depth to water and the presence of free product or sheen <br /> The monitoring data and the ground water elevations are summarized in <br /> Table 1 The ground water flow direction during the most recent <br /> quarter is shown on the attached Figure 1 <br /> Ground water samples were collected on September 9 , 1994 Prior to <br /> sampling, the wells were each purged of between 5 and 8 gallons of <br /> water During purging operations, the field parameters pH, tempera- <br /> ture, and electrical conductivity were recorded and are presented in <br /> Table 2 Once the field parameters were observed to stabilize, and <br /> where possible, a minimum of approximately four casing volumes had been <br /> removed from each well, samples were then collected using a clean <br /> Teflon bailer The samples were decanted into clean VOA vials and/or <br /> one-liter amber bottles, as appropriate, which were then sealed with <br /> Teflon-lined screw caps, labeled, and stored in a cooler, on ice, until <br /> delivery to a state-certified laboratory MPDS Services , Inc <br /> transported the purged ground water to the Unocal Refinery located in <br /> Rodeo, California, for treatment and discharge to San Pablo Bay under <br /> NPDES permit <br /> ANALYTICAL RESULTS <br /> The ground water samples were analyzed at Sequoia Analytical Laboratory <br /> and were accompanied by properly executed Chain of Custody documenta- <br /> tion The analytical results of the ground water samples collected to <br /> date are summarized in Table 3 The concentrations of Total Petroleum <br /> Hydrocarbons (TPH) as gasoline and benzene detected in the ground water <br /> 2401 Slan yell (Drive Suile 400 Concord CA 94520 <br /> TEL (510) 602 5120 FAX (510)689 1918 <br />