My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0007353
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
15406
>
3500 - Local Oversight Program
>
PR0545741
>
ARCHIVED REPORTS_XR0007353
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/8/2020 12:50:50 PM
Creation date
6/8/2020 12:36:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0007353
RECORD_ID
PR0545741
PE
3528
FACILITY_ID
FA0006284
FACILITY_NAME
YAMADA BROS INC
STREET_NUMBER
15406
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
18917007
CURRENT_STATUS
02
SITE_LOCATION
15406 S TRACY BLVD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />' Quarterly Report - Second Quarter 2002 <br /> • YAMADA BROTHERS <br />' 15406 South Tracy Boulevard, Stockton, California <br />' 1.0. INTRODUCTION <br />' In accordance with the request of Mr Bob Yamada of Yamada Brothers, Inc , Advanced <br /> GeoEnvironmental, Inc (AGE) has prepared this quarterly report for the property located at 15406 <br /> South Tracy Boulevard, Stockton, California The scope of work included quarterly ground water <br />' monitoring and preparation of this report The location of the site and the Immediately surrounding <br /> area are illustrated on Figure 1, structures and monitoring well locations on the site are Illustrated <br /> on Figure 2 Background Information is summarized in Preliminary Site Assessment Report, dated <br />' 12 February 1999, and in Additional Site Assessment Report, dated 12 December 2001, both <br /> prepared by AGE <br /> 20 PROCEDURES <br /> Quarterly ground water monitoring was performed on 17 June 2002 Field work was performed in <br /> accordance with the Central Valley Regional Water Quality Control Board(CVRWQCB) and San <br /> • Joaquin County Environmental Health Department (EHD) guidelines for investigations of <br /> underground storage tank (UST) sites and sampling ground water monitoring wells, respectively <br />' 2 1 WELL MONITORING AND EVACUATION <br /> On 17 June 2002, a Sohnst water level meter was used to measure the depth to ground water in the <br /> three wells relative to the tops of the well casings (well heads) The ground water elevations and <br /> gradient were determined from this data (Table 1) <br /> rAfter recording water level measurements, disposable plastic bailers were used to purge the <br /> monitoring wells of standing water Approximately 7 5 to 10 gallons of water were removed from <br /> each well(approximately 3 casing-water volumes) Ground water temperature,pH and conductivity <br /> were measured at regular intervals during the purge process using an Oakton water analyzer Field <br /> data sheets are included in Appendix A Purged water was stored on site in labeled, 55-gallon DOT- <br /> approved drums <br /> Domestic well DW-1 was purged by opening the purge valve and allowing the holding tank to be <br /> emptied Following complete discharge of the holding tank the pump was allowed to operate for at <br /> least one minute and a sample was collected from the sampling port located on the supply line <br /> between the well head and the holding tank <br /> I <br /> • <br /> Advanced GeoEnvironmental,Inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.