My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0007358
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
15406
>
3500 - Local Oversight Program
>
PR0545741
>
ARCHIVED REPORTS_XR0007358
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/8/2020 12:51:41 PM
Creation date
6/8/2020 12:45:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0007358
RECORD_ID
PR0545741
PE
3528
FACILITY_ID
FA0006284
FACILITY_NAME
YAMADA BROS INC
STREET_NUMBER
15406
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
18917007
CURRENT_STATUS
02
SITE_LOCATION
15406 S TRACY BLVD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br />' Quarterly Report - First Quarter 2001 <br /> . YAMADA BROTHERS <br /> 15406 South Tracy Boulevard, Stockton, California <br /> 1 <br /> Z.O. INTRODUCTION <br />' In accordance with the request of Mr Bob Yamada. of Yamada Brothers, Inc , Advanced <br /> GeoEnvironmental, Inc (AGE)has prepared this quarterly report for the property located at 15406 <br />' South Tracy Boulevard, Stockton, California The scope of work included quarterly ground water <br /> monitoring and pi eparation of this report The location of the site and the immediately surrounding <br />' area are illustrated on Figure 1, structures and monitoring well locations on the site are illustrated <br /> on Figure 2 Background information is summarized in the Preliminary Site Assessment Report - <br /> February 1999, prepared by AGE <br /> 1 <br /> 2.0. PROCEDURES <br />' Quarterly ground water monitoring was performed on 20 March 2001 Field work was performed <br /> in accordance with the Central Valley Regional Water Quality Control Board(CVRWQCB) and San <br /> I Joaquin County Public Health Services -Environmental Health Division(PHS-EHD) guidelines for <br /> the investigation of underground storage tank (UST) sites and sampling ground water monitoring <br /> lie wells <br /> 21 MONITORING WELL PURGE PROCEDURES <br /> On 20 March 2001, a S olinst water level meter was used to measure the depth to groundwater in the <br /> three wells relative to the tops of the well casings (well heads) The ground water elevations and <br /> Igradient were determined from this data(Table 1) <br />' After recording water level measurements, a two-stage submersible pump was used to purge each <br /> monitoring well of standing water Approximately 7 5 to 10 gallons of water were removed from <br /> each well(approximately 3 casing-water volumes) Ground water temperature,pH and conductivity <br /> were measured at regular intervals during the purge process using a Hydac water analyzer Field data <br /> sheets are included in Appendix A Purged water was stored on site in labeled, 55-gallon DOT- <br /> approved drums <br /> IDomestic well DW-1 was purged by opening the purge valve and allowing the holding tank to be <br /> emptied Following complete discharge of the holding tank the pump was allowed to operate for at <br /> I least one minute and a sample was collected from the sampling port located on the supply line <br /> between the well head and the holding tank <br /> I <br /> • <br /> I <br /> Advanced GeoRavironmentai,Inc <br /> I , <br />
The URL can be used to link to this page
Your browser does not support the video tag.