Laserfiche WebLink
r <br /> Cotilornia Test 301 <br /> 1978 <br /> Litre 6:"Li',ater added—ntl."includes tilt'Milliliters e gisis;dc nt thickness to its intercept with tine Curreet <br /> Of water added for "soaking" plus the final tivater traffic indc-x .,;:lee. Vtorn this point project a vertical <br /> added during the mixing oper:atian just prior to corn- line to read the R•valuc. <br /> paclian !fart 1). <br /> Line %`:"Wnter added--percent" is calculated ill D. CONTROL <br /> the manner indicated in the:method for calculating 1. Refer to California 'fest 102 for detail:on the <br /> the densities of 11-value test speri•nens (fart VI), rnochanics of the Stabilometer including its oprra- <br /> Lhie S.•"Moisture at compaction—percent"is the tion,calibration and the installation of the Neoprene <br /> stun of the percent initial moisture and the perevill [diaphragm. <br /> razoisture added' z. The currrct Volumetric adjustment of the ;air <br /> Lb2osO.,md 10.-The height of briquette (to nearest cell in the la}•drraulic chamber of the stabilometer is <br /> 0-M inch) and the wet weight of briquette (granas) neeesstry in order to establish standardized horizon- <br /> arc determined prior to the exp:uasion pressure test. tal pressure and displacement readings.The Follow- <br /> These Values are used with the moisture at compac- ing is an outline of this calibration procedure: <br /> lion in the density computations (part I11). a. Adjust bronze nut on stabilometer stage base so <br /> Lire I I: "P,cnsity—pounds per cubic foot"is cal- that the top of the stage is 314 inches below the <br /> culatcd in accordance with the method ofcalculating bottom of the upper tapered ring. Perform till <br /> the densitcs of 11-slate test specimens (Part N'1), tests at this setting. <br /> LfiI to 14inclusia•e: The stabilometer data are b, Adjust tlae testing machine so that the base <br /> entered as they are determined during the perform• plate moves upward at a rat_of 0.05 inches per <br /> ance of the stabilometer test. minute when unloaded.This adjustment is per- <br /> Line 15.The exudation pressure is recorded as the formed with the stabilometer and stage base on <br /> compressive stress in psi at which moisture is exuded the platen. The hydraulic testing machines <br /> from the specimen as indicated by the exudation must be run several minutes before the oil <br /> pressure device (Part I11). Nvarms up sufficiently to maintain a constant <br /> Litre 16.-"Stab.Thick-Feet"is calculated in accord- speed. <br /> -nice with the method of calculating design thickness c. Put the standard metal specimen in place in the <br /> of pavements, (Part V!II). This calculation is only stabilometer.Seat it firmly on the stage and by <br /> required when expansive soil has been tested, holding it in place with either the hand or a <br /> Luno 17.•In the space provided for expansion pres- confining load of 100 pounds in the testing ma. <br /> sure, the deflection measurement of the calibrated chine, turn the pump to a pressure of exactly a <br /> bar in the expansion pressure device multiplied bL <br /> psi,Adjust the turns indicator dial to zero.Turn <br /> 10,000 is entered,and it is called the"dial reading." the pump handle at an approximate rate of two <br /> Referring to the example given on the work- card turns per second until the stabilometer dial <br /> included in Part V11 of this test method (Figorc 18), reads 100 psi.The turns indicator dial shall read <br /> dial readings of 91 and 18 correspond to deflection 2.00 ± ,05 turns.If it does not,the air in the cell <br /> measurements of.0041 and .0015 inches,respective- roust be adjusted. Remove or add air by means <br /> 1? of the salve and the rubber bulb,and repeat the <br /> Line 1&To obtain expansion pressure thickness in displacement measurement after each air <br /> feet,divide the expansion pressure on line 18 by 30, change until the proper number of turns is ob- <br /> Nci'rr:Line 19. Use the structural design chart in tained. Release horizontal pressure and remove <br /> figure 20 to determine the R-value by expansion. the standard metal specimen.The stabilometer <br /> T Project a horizontal line from the required gravel is now ready for testing specimens. <br /> 13 <br />