Laserfiche WebLink
r <br /> kn KLEINFELDER <br /> 16 <br /> 3 Kleinfelder recommends performing a limited pump test in monitoring well MW-1 to <br />' assess groundwater hydraulic properties such as draw-down, hydraulic conductivity and <br /> estimating a radius of influence to pumping This information would be useful in <br /> evaluatmg potential remedial efforts Kleznfelder recommends initially purging any product <br />' layer from the well prior to conducting the pump test During the pump test, purge water <br /> should be filtered through a carbon filter media followed by contauiment Testing of the <br /> effluent is recommended to assess potential disposal options of the contained groundwater <br /> 4 Kleinfelder recommends that a copy of this report be submitted to San Joaquin County <br />' EHD and the CVRWQCB for their review and comment <br /> 5 The purge water currently stored on-site should be evaluated and properly disposed of by <br />' the Client Kleinfelder can assist the Client in the disposal process at an additional charge if <br /> requested by the client <br /> This report, and the conclusions and recommendations presented in this Executive Summary, are <br /> subject to the "Limitations" presented in Chapter 7 of this report Any party (other than General <br /> Mills or regulatory agencies having enforcement jurisdiction for this site) who would like to use <br /> this report shall notify Kleinfelder, Inc of such intended use in writing for permission <br /> M <br /> 1 <br /> i <br /> i <br /> 1 <br /> I <br /> 1 <br /> 28209 T03/STO4RI402/DH 1v Page 10 of 11 <br /> 1 102004,Kleinfelder, Inc October 20,2004 <br />