Laserfiche WebLink
�} The groundwater in the vicinity of the site is unconfined Groundwater elevation at the <br /> site varies from a wet year high of 25 feet bgs to at least 50 feet bgs during the previous <br /> drought period Groundwater flow direction at the site has varied from north to south <br /> through the northeast and southeast quadrants <br /> QUARTERLY GROUNDWATER MONITORING, 12/19/03 <br /> WEGE colleUed quarterly groundwater samples from the four monitor wells at the site <br /> on December 19, 2003 See Appendix A for QA/QC, details, methods, procedures, <br /> abbreviations, and acronyms used in sampling and analysis See Appendix B for copies <br /> of the field data sheets <br /> DEPTH TO WATER MEASUREMENTS <br /> WEGE measured depth to water in all four wells on December 19, 2003 The <br /> measurements were made from the surveyed elevation datum at the top of casing at each <br /> well using an electrical air/water interface probe (Table 1) No free product or product <br /> sheen was observed in any of the monitor wells <br /> COLLECTION AND CERTIFIED ANALYSIS OF GROUNDWATER SAMPLES <br /> Following depth to water measurements, WEGE purged approximately three well <br /> volumes of water from each monitor well using a truck mounted submersible 2" <br /> Grundfoss pump and disposable one half inch diameter PVC tubing An in-line cell <br /> equipped with a Hanna pH, temperature, and conductivity probe and meter were used to <br /> measure water quality parameters at one minute intervals during the well purging A <br /> calibrated flow meter was placed between the in-line cell and waste water tank to <br /> measure the rate and total volume of water purged from each well The volume of water <br /> purged from each well was noted on the field data sheets (see Appendix B) <br /> Purging rates were maintained at <1 gallon/minute so that drawdown in the well did not <br /> exceed 20% of the original well volume A groundwater sample was then collected by <br /> severing the PVC tubing at a point between the Grundfoss pump and in-line cell while <br /> the pump continued to run and decanting the groundwater into three 40 ml VOA vials <br /> containing 0 5 ml HCL acid as a preservative <br /> The samples were delivered with accompanying chain of custody documentation to Kiff <br /> Analytical Laboratories (DHS Certification#2236) The certified laboratory analyzed the <br /> groundwater samples from each monitor well for concentrations of TPH-G, BTEX and <br /> MTBE using EPA method 8260B <br /> DISPOSITION OF WASTEWATER <br /> The 67 gallons of wastewater that were generated from purging of the monitor wells were <br /> temporarily contained on-site in a labeled 55 gallon dot approved drum <br /> 2 Are Pumn OM 9-12 2001 <br />