Laserfiche WebLink
1 � <br /> Contamination was detected in the deepest recovered sample from MW-6 at a depth of 65 feet bsg <br /> One soil sample collected from the pilot boring for MW-8 contained 1,2-DCA at a concentration of <br /> 15 mg/kg Soil samples from the pilot boring for MW-7 did not contain detectable concentrations <br /> of analytes of concern TPH-g, BTEX and 1,2-DCA were detected in the initial ground water <br /> samples collected from MW-6, MW-7 and MW-8 Details of the procedures and results of the <br /> monitoring well installation were presented in Monitoring Well lnstallatzon Report-Fourth Quarter <br /> 2000, dated 16 January 2001, prepared by AGE <br /> VERTICAL SITE ASSESSMENT <br /> On 10 October 2002, a soil boring (CPT-01) was advanced vertically on-site to a total depth of <br /> approximately 147 feet below surface grade (bsg), utilizing CPT technology to characterize the <br /> geological and hydrogeological framework and to identify potential contaminant-migration <br /> pathways beneath the site Based on the CPT lithologic sounding data,depth-discrete"grab"ground <br /> water samples and a soil sample were collected in a"twin"soil boring placed immediately adjacent <br /> to CPT-01, the water samples collected were assigned the boring designation of the initial CPT <br /> boring (CPT-1) However, the twin boring could only achieve a maximum sampling depth of <br /> approximately 117 feet bsg before encountering refusal <br /> LABORATORY RESULTS OF SOIL/CPT"GRAB" GROUND WATER SAMPLES <br /> Only one soil sample(CPT 1-1-85)was collected and submitted for analysis during the fourth quarter <br /> 2002 TPH-g,toluene,ethylbenzene, and total xylenes were detected in the sample at concentrations <br /> of 1 6 milli grams/kilogram, 16 micrograms/kilogram(µg/kg),5 1 µg/kg and 24µg/kg,respectively, <br /> benzene was not detected in the soil sample <br /> A total of two "grab"ground water samples were collected from CPT-01,between 96 and 100 feet <br /> bsg and between 113 and 117 feet bsg TPH-g was detected in both samples at concentrations of <br /> 13,000 gg/1 and 140,000 µg/l, respectively BTEX compounds were detected in both samples at <br /> concentrations as high as 4,600 µg/1 benzene, 16,000 µg/l toluene, 2,100 µg/1 ethylbenzene and <br /> 11,000 gg/l total xylenes(CPT-01-113-117) In addition, 1,2-DCA was detected in both samples at <br /> concentrations of 8 8 µg/1 and 250 gg/l,respectively and EDB was detected in sample CPT-O1-113- <br /> 117 at a concentration of 90 µg/l <br /> ADDITIONAL MONITORING WELL INSTALLATION/ABANDONMENT <br /> Between 14 October and 23 October 2002, soil borings were advanced at the site to install <br /> monitoring wells MW-8B,MW-9A/B, MW-10A/B,MW-11A/B and MW-12A/B) and one ground <br /> water momtoring/extractionwell EX-1 Pilot borings MW-8B,MW-9AB,MW-IOA/B,MW-11A/B <br /> and MW-12AB were completed as ground water monitoring wells using two-inch diameter PVC <br /> casing with 0 020-inch slotted screen The screen was installed from approximately 15 to 35 feet bsg <br /> Advanced GeoEnvironmental,Inc <br />