My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/30/2020 8:37:28 AM
Creation date
6/11/2020 10:12:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
137
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WALTON <br /> ENGINEERING, INC. <br /> P.O. Box 1025 9163721888 PH <br /> 3900 Commerce Drive 9163731172 FAX <br /> West Sacramento,CA 95691-1025 CA Contractor's License#617238 <br /> Customer Job Location Work Order# 137805 <br /> Vixxo 7-Eleven#2369-19976 Scheduled Date: 12/17/2020 <br /> 7000 E Shea Blvd,Suite H1970 1399 N.Main Street Scheduled Time: 12:00:OOPM <br /> Scottsdale,AZ 85254-6137 Manteca,CA 95336 Contact: FM <br /> Customer PO#: 1-4769786952 <br /> Phone: 2092393252 Facility: W31155-017 <br /> Station#: 19976 <br /> Contract# <br /> Work To Be Performed: Call type: P1 Service Call ** <br /> Dispenser-All dispenser slow <br /> Work Performed: <br /> 12/16/20 Performed Job Safety Analysis and uploaded JSA form to Walton Work Orders. <br /> 12/16/20 <br /> All running slow. <br /> Reset 87 leak detector and all is dispensing around 7.2 GPM. <br /> All in service and returned all dispensed products to storage.Observed customers dispense with no problems.Site has been having slow <br /> flow problems and will need to order leak detector and return with confined space and lift truck and with tester to test 3.0 leak test following <br /> replacement per manufacture requirements.Left paper work on site in compliance box and filled out maintenance log on 121620 at 20:05 PM <br /> REB. <br /> 12/17/20 Performed Job Safety Analysis and uploaded JSA form to Walton Work Orders. <br /> 12/17/20 All down. <br /> Returned and shut site down and conducted LOTO.Checked opening time of 87/91 leak detectors and 91 is good but 87 opens in seven <br /> seconds.Replaced faulty leak detector causing 87 Oct slow flow and left old one on site in solid tagged hazmat drum dated today and is 1/4 <br /> full. <br /> Tested for leaks and no leaks found and opening time is under four seconds.Returned all dispensed product to storage and left site shut <br /> down pending arrival of tester today to test LD at a 3.0 GPH leak rate at 10 PSI as per manufacture requirements and then he will open site <br /> upon passing results.Left paper work on site in compliance box and filled out maintenance log on 121720 at 12:28 PM REB. <br /> 12/17/20 Arrived onsite to test and certify 87 MLLD after replacement.Tested MLLD per manufacture requirement,where passing results were found. <br /> New opening time is less than 1 second.Test fuel was returned to 87 tank.Placed site back into fuel service.Copy of this work order placed <br /> in compliance box. <br /> 12/17/20 JSA Completed. <br /> Open Problems: <br /> 12/16/20 Two man with confined space including certified tester to test LD upon replacement per manufacture. <br /> 1 EA 301-81010 Vaporless 99LD-2000-S I Leak Detector,VMI Mechanical 7 <br /> 1 EA 301-97066 Red Jacket 144-193-1 Packer Discharge Seal <br /> 1 EA 301-97078 Red Jacket Functional Element Assy.,Adjustable <br /> 1 EA 301-97074 Red Jacket 144-183-5 Check Valve w-Spring,Old Style STP 7 <br /> 12/17/20 Walton testing to arrive today to test 87 Leak detector and place site in service. <br /> Parts Used: <br /> Qty Part# Mfg Mfg Part# New Serial# Desc Reason <br /> 1 301-81010 VAPORLE: 99LD-2000-S ! 19081072 Leak Detector,VMI Mechanical 7 Normal Wear <br /> -1 301-81010 VAPORLEr 99LD-2000-S ! Leak Detector,VMI Mechanical 7 <br /> 1 711-81010 VAPORLE,4 99LD-2000-S 7-11 Leak Detector,VMI Mechanical <br />
The URL can be used to link to this page
Your browser does not support the video tag.