My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/30/2020 8:37:28 AM
Creation date
6/11/2020 10:12:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
137
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IVED <br /> z , I , ,. <br /> swxcB, January 2002 � U C 0 6 Z 020 Page 1 of 1 <br /> 5 . SECONDARY PIPE TESTING <br /> Test Method Developed By : Piping Manufacturer Industry Standard Professional Engineer <br /> f-" <br /> Other (Specify) ENVIRONMENTAL HEALTH <br /> Test Method Used By : F Pressure F' Vacuum I` ydrostatic ' <br /> F Other (Specify) <br /> Test Equipment Used : gauge Equipment Resolution : .20 <br /> (Tank T4:UNLEADED (Tank T5 :PREMIDM <br /> - RUL) STP PUL) STP Containment <br /> Containment 1 to 1/2 1 to 1/2, 3/4 <br /> Piping Material: 3/4 dw fiberglass <br /> Piping Manufacturer: dw fiberglass smith <br /> Piping Diameter: smith 3 in , in. in. <br /> Length of Piping Run : 3 in. 90 ft ft. ft. <br /> Product Stored : 90 $. PUL <br /> Method and location of RUL <br /> sump <br /> pi in run isolation : <br /> sump <br /> Wait time between applying <br /> pressure/vacuum/water and 15 min min min <br /> starting test: 15 min <br /> Test Start Time: 09:26:00 <br /> Initial Reading (Rt): 09:26:005400000 PSI <br /> Test End Time : 5.00000 PSI 10:26:00 <br /> Final Reading10:26:00 <br /> (R 5.00000 PSI <br /> F)� <br /> Test Duration : 5.00000 PSI I hr <br /> Change in Reading (RF-RI): 1 0.00000 PSI <br /> Pass/Fail Threshold or 0.00000 PSI <br /> +/- 0.00000 +/- +/- <br /> Criteria: +/- 0. 00000 <br /> Test Result Pass <br /> • Pass <br /> Comments - (include information on repairs made prior to testing, and recommended follow- aap for• failed tests) <br /> W0 : 2345875 <br />
The URL can be used to link to this page
Your browser does not support the video tag.